175, 177, 179
Bedienungshandbuch
24
Frequenzzähler-Empfindlichkeit
Eingangsbereich [1] [2] Typische Empfindlichkeit (Effektivwert Sinuswelle)
2 Hz bis 45 Hz 45 Hz bis 10 kHz 10 kHz bis 20 kHz 20 kHz bis 50 kHz 50 kHz bis 100 kHz
Volt AC
600 mV Unspezifiziert [3] 80 mV 150 mV 400 mV Unspezifiziert [3]
6 V 0,5 V 0,6 V 1,0 V 2,8 V Unspezifiziert [3]
60 V 5 V 3,8 V 4,1 V 5,6 V 9,6 V
600 V 50 V 36 V 39 V 45 V 58 V
1.000 V 500 V 300 V 320 V 380 V NA
Volt DC
6 V 0,5 V 0,75 V 1,4 V 4,0 V Unspezifiziert [3]
60 V 4 V 3,8 V 4,3 V 6,6 V 13 V
600 V 40 V 36 V 39 V 45 V 58 V
1.000 V 500 V 300 V 320 V 380 V NA
Ampere AC / DC mA 5 mA 4 mA 4 mA 4 mA [4] NA
A 0,5 A 0,4 A 0,4 A 0,4 A [4] NA
[1] Maximales Eingangssignal für angegebene Genauigkeit = 10-facher Bereich oder 1.000 V.
[2] Rauschen bei niedriger Frequenz und Amplitude überschreitet unter Umständen die Genauigkeitsspezifikation.
[3] Nicht-spezifiziert, jedoch brauchbar je nach Qualität und Amplitude des Signals.
[4] In mA- und A-Bereichen ist die Frequenzmessung mit 30 kHz spezifiziert.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 177 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 177 in the language / languages: German as an attachment in your email.

The manual is 1,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 177

Fluke 177 User Manual - English - 50 pages

Fluke 177 User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info