539969
35
Zoom out
Zoom in
Previous page
1/48
Next page
35
GB
Read the sections below to learn more
about each operating element’s function.
Technical Data

Mains connection ............230 V~, 50 Hz
Power consumption ...............1100 Watt
Suction lift ...................................... 7 m
Max. discharge rate ................4.600 l/h
Max. discharge head .................... 45 m
Max. water temperature ................ 35 °C
Hose connection ............................... 1“
Turn-on pressure ..........0,2 MPa (2,0 bar)
Turn-off pressure ........0,45 MPa (4,5 bar)
Maximum pressure ..........1 MPa (10 bar)
Safety class ......................................... I
Degree of protection ........................IPX4
Noise pressure
level (L
pA) ........74 dB(A); KpA = 3,0 dB(A)
Noise performance level
(measured) / (L
WA)
...............88,2 dB(A ); K
WA = 2,89 dB(A)
Noise performance level
(guaranteed) .............................91 dB(A)
The stated values relate to the use of the
automatic domestic water pump without
automatic switch DSK-19. The values may
differ slightly as a result of use with the au-
tomatic switch.
General Description
Scope of Delivery
- Home water dispenser
- Automatic switch
- Connecting piece
- Carrying handle
- Srews
- Instruction Manual
The diagram of the most impor-
tant functional elements can be
found on the foldout side.
Overview
A
1 Water outlet, automatic switch
2 Protective cap for male thread
3 Protective cap for female thread
4 Water inlet, home water dispens-
er
5 Protective cap for female thread
6 Water outlet, home water dis-
penser
7 On/Off switch
8 Power cable
9 Carrying handle
10 Srews
11 Filler screw
12 Connecting piece
13 Draining screw
14 Protective cap for male thread
15 Water inlet, automatic switch
16 Alarm” indicator
17 Restart switch
18 “Pump On” indicator
19 “Power On” indicator
20 Automatic switch
Functional description
The home water dispenser pumps water
automatically. The pump will turn on and
convey water at turn-on pressure. The turn-
on point is set in the factory and cannot be
adjusted by the user.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Florabest FHA 1100 B2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Florabest FHA 1100 B2 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info