18. Troubleshooting guide
Motor not running
Cause Remedy
- Power supply not connected
- Impeller blocked, thermostat has switched off
- Check voltage supply
- Take pump apart and clean it
Pump not priming
Cause Remedy
- Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake valve leaking
- Intake cage (intake valve) blocked
- Max. intake height exceeded
- Place intake valve in water
- Fill pump housing with water
- Check sealing of intake line
- Clean intake valve
- Clean intake cage
- Check intake height
Insuffi cient pumping rate
Cause Remedy
- Intake height too high
- Intake cage soiled
- Water level falling rapidly
- Pump performance reduced by foreign bodies
(sand, stones, etc.)
- Check intake height
- Clean intake cage
- Place intake valve lower down
- Clean pump and replace wearing parts
Thermostat switches off the pump
Cause Remedy
- Motor overloaded, excessive friction caused
by foreign bodies
- Dismantle and clean pump, prevent intake of
foreign bodies (fi lter)
Caution! The pump must not run dry.
Anleitung_4180301.indb 41Anleitung_4180301.indb 41 18.09.12 10:1518.09.12 10:15
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Florabest FGPA 1000 A1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Florabest FGPA 1000 A1 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info