539580
38
Zoom out
Zoom in
Previous page
1/46
Next page
GB
- 38 -
The pumping of aggressive liquids (acid,
alkali, silo seepage, etc.) and liquids with
abrasive (emerizing) substances (sand) must
likewise be avoided.
5. Technical data
Mains connection: ...........................230V ~ 50 Hz
Power rating: ..............................................1000 W
Max. delivery rate ...................................4600 l/h
Max. delivery head .........................................45 m
Max. delivery pressure ...........4.5 bar (0.45 MPa)
Max. suction height ........................................... 7 m
Pressure and suction connector: ..............................
..................... approx. 33.3 mm (R1 female thread)
Max. water temperature.................................35°C
Sound pressure level L
pA
....................72.03 dB (A)
Uncertainty K
pA
.......................................... 3 dB (A)
Peak noise level:
Measured ........................................... 84.62 dB (A)
Uncertainty K
WA
.......................................... 3 dB (A)
Guaranteed ..............................................86 dB (A)
Protection class .........................................................I
Protection type ..................................................IPX4
Weight ............................................................8.9 kg
6. Operating instruc tions
As a basic principle, we recommend the use of
a preliminary fi lter and a suction set with suction
hose, intake cage and non-return valve, in order
to prevent long priming periods and unnecessary
damage to the pump as a result of stones and so-
lid foreign bodies.
7. Fitting the carry handle
Fasten the carry handle with the 2 screws
supplied (see Fig. 2).
8. Fitting the suction hose
Fit the suction hose as illustrated in Fig. 3.
Make sure that the end of the adapter (Fig. 1/
Item 11) with the sealing ring (Fig. 1/Item 12) is
screwed into the equipment.
9. Mains connec tion
The mains connection needs a 230 V ~ 50 Hz
shock-proof socket. Minimum 10-amp fuse
required. Please ensure that the power socket
is easily accessible.
Switch on/off at the built-in switch (see Fig.
1/Item 2).
The motor is protected from overload or blo-
ckage by a built-in temperature monitor. In
case of overheating the temperature monitor
automatically switches the pump off. After the
equipment has cooled down, the pump will
switch on again automatically.
10. Fitting a suction pipe
Screw a suction pipe (min. 19 mm (3/4“)
plastic pipe with spiral reinforcement) either
directly or with the aid of a threaded nipple
approx. 33 mm (R1) male thread onto the
intake line connection approx. 33 mm (R1)
female thread of the pump (Fig. 1/Item 5).
The suction hose should have an intake valve.
If the intake valve cannot be used then a non-
return valve should be installed in the intake
line.
Position the intake line so that it rises from the
water withdrawal point to the pump. Avoid
positioning the intake line higher than the
pump as this would delay the escape of air
bubbles from the intake line and impede the
priming process.
Install the intake and discharge lines in such
a way that they do not exert any mechanical
pressure on the pump.
The intake valve should be low enough in the
water to ensure that the pump will not run dry
if the water level falls.
Anleitung_4180301.indb 38Anleitung_4180301.indb 38 18.09.12 10:1518.09.12 10:15
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Florabest FGPA 1000 A1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Florabest FGPA 1000 A1 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info