10. Cleaning and care
Cleaning
Always wash the pressure cooker after you have used it.
-Removethesiliconegasketfromthelidandwashitbyhand.
-Rinsethecontrolvalveunitunderrunningwaterorremoveandcleanifnecessary.
-Removethelidhandlewhenneeded(atthelatest,whenitlooksdirty)andrinseitunderrunningwater.
- The pot, lid (without the silicone gasket, control valve unit, and lid handle), and insets can also be placed in the
dishwasher.
Please note:
- To clean, use clear, hot water and dishwashing liquid and a dishwashing sponge or a soft brush. Do not use pointed,
rough or sharp objects. If the inside or bottom is very dirty, you can use the rough side of the sponge.
- Do not let food residues dry onto the cooker, and do not store foods in the cooker for a long time, as this could
cause stains in the stainless steel and changes in the surface.
- To maintain the stainless steel surface, use Fissler Stainless Steel Care regularly. It is outstanding for removing rain-
bow discolorations or films.
- When cleaning the cooker parts in the dishwasher, use only conventional household dishwashing products in the
amounts recommended by the manufacturer. Do not use industrial detergents or highly concentrated cleaning
products.
Mounting the control valve unit and lid handle
Control valve unit (Fig. A-5)
To remove:SeeFig.R
Undothefasteningscrew(Fig.A-21)byturningitcounter-clockwiseandremovethecontrolvalveunit.Thefastening
screw can be loosened without any tools simply by using a one cent coin.
To mount: See Fig. S
Insert the control valve unit in the proper place from above into the lid (in the centre of the pin), screw in the
fastening screw in a clockwise direction from the bottom, and tighten firmly.
Lid handle (Fig. A-1)
To remove: See Fig. T
Removethelidhandlebyturningthelidscrew(Fig.A-19)ontheinsideofthelidinacounter-clockwisedirection.
To mount: SeeFig.U
Hold the lid handle in your hand and place the lid on it in the appropriate position. Turn the lid screw in a clockwise
direction and tighten it firmly.
Storage
Thesiliconegasketshouldbestoredinadarkplace(protectedfromsunlightandUVradiation),dryandclean.The
silicone gasket will last longer if you place the lid upside down on top of the pot after it is cleaned, so that the ring
will not be crushed.
Maintenance
The parts of the pressure cooker that are subject to wear must be replaced regularly. You will find additional informa-
tion on this in Chapter 12.
Cleaning and care
41
19


Need help? Post your question in this forum.

Forumrules
1

Forum

fissler-vitaquick

Reset search

  • The pressure valve does not rise and steam escaping around it. All parts are new. This happened after mistakenly did not have lid locked on and cooker was on with steam escaping and no pressure. When I corrected lid and locked it properly this problem occurred. Please advise.
    Thank you.
    Susan Submitted on 16-11-2021 at 00:22

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fissler vitaquick at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fissler vitaquick in the language / languages: English as an attachment in your email.

The manual is 5,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fissler vitaquick

Fissler vitaquick User Manual - English - 24 pages

Fissler vitaquick User Manual - German - 18 pages

Fissler vitaquick User Manual - German - 26 pages

Fissler vitaquick User Manual - Dutch - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info