Operation Instructions
INITIAL WATER TREATMENT
Add 1 x Water Treatment Tablet per full tank. DO NOT, UNDER ANY CIRCUMSTANCE, USE A WATER
TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. Your unit purchase includes 4 x
Water Treatment Tablets, which is sufficient for several years of use. To purchase additional chlorine
tabs, please consult your nearest regional dealer/distributor or check our website at
www.firstdegreefitness.com
a) Filling requires a large bucket (not Supplied) and the supplied
water Funnel and hose[5]. Filling will take approximately 8
liters of water.
b) Open the yellow fill plug on the back of the tank and insert
hose (rotating the impeller slightly may be necessary to allow
the hose to pass). Note: In areas where tap water quality is
known to be poor, FDF recommends the use of distilled water.
c) Move the Tank Adjuster Handle to Level 20 and begin filling.
Do not fill the tank higher than the level indicator on the front
of the clear shell.
d) Once filling is complete follow the water treatment procedure
below, then replace the tank plug.
CAUTION
Use a drop cloth under
the tank when filling to
avoid damage floor or
carpet.
Do not fill past the
calibration mark as
indicated on the tank
level sticker or water
spillage may occur.
WARNING
Impeller blades are
sharp! Do not Place
fingers in tank to
adjust impeller position.
It is recommended to
use the end of the hose
Should the impeller
require adjustment.
REQUIRED
Funnel and Hose [5].
Note: The Lower Black Tank Plug is Permanently Sealed.
Yellow Tank Plug
Filling Hose and Funnel
Tank Filling and Water Treatment
Long Term Water Treatment:
Do not use any water treatment other than the tablets supplied with this unit. For replacement tablets,
contact your local First Degree Fitness distributor.
Water treatment schedules for the FLUID ROWER will vary according to the fluid tanks exposure to
sunlight, but expect 8-12 months near a bright, sunlit window and 2 years or more for a darker location.
At the point of finding the water slightly cloudy, add a Water Treatment Tablet.
Long Term Water Treatment and Basic Operation
Resistance:
Resistance is determined by the Level Indicator on the front of the tank.
Level 1 indicates lightest resistance and level twenty the heaviest. Allow
three to four strokes, after moving the Level Indicator, for the new level to
be achieved. Note computer level must be changed to provide accurate input
at each individual tank level. Consult your IPM computer manual (included) for
details.
Vertical Storage:
The FLUID ROWER can easily be stored in a vertical position. For safety,
choose a suitable location, such as a corner of a room. It is recommended
that something soft (such as carpet or a small towel) be placed under the
rowing pulley of the unit to avoid chipping or floor damage. Note: Move with
caution as the unit is heavy. Pick up from back and pull at 45 degree angle.
Level Indicator
CAUTION: It is strongly recommended that a drop cloth be used under the fluid tank whenever the
tank plug is opened for water treatment.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for First Degree VORTEX VX-3 FLUID ROWER at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of First Degree VORTEX VX-3 FLUID ROWER in the language / languages: English as an attachment in your email.

The manual is 7,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info