INITIAL WATER TREATMENT
Add 1 x Water Treatment Tablet per full tank. DO NOT, UNDER ANY CIRCUMSTANCE, USE A WATER
TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. Your unit purchase includes 4 x
Water Treatment Tablets, which is sufficient for several years of use. To purchase additional Water
Treatment Tablets, please consult your nearest regional dealer/distributor or check our website at
www.firstdegreefitness.com
The Adjustable Resistance (AR) Tank, developed and patented by FIRST DEGREE FITNESS. offers a true
multi-level experience. Water is moved between the "storage" and "active" chambers of the AR Tank. Your
new Rowing Ergometer can adapt - at the turn of a dial - to the resistance preferred by each user.
Getting Started
To achieve minimum resistance, select "MIN" on the tank adjuster. It takes 10 strokes to fill the central
(storage) tank, leaving a minimal amount of water in the outer (active) tank. This process is always
required if minimum resistance is desired. Row hard at a steady pace (20 to 25 strokes per minute [SPM])
and put some effort into the stroke, ensuring that good form is maintained. You can make adjustments to
the resistance level while you row. Your AR Tank will adapt almost instantly to increases in resistance but will
take up to 10 strokes to reduce the effort required, as the central (storage) tank fills up.
Developing Your Routine
Once you have found a level that gives you the exercise required, changes can be made to SPM and to stroke
intensity to further vary your energy input. Interval training is used by most Rowers, where a period of low
intensity is combined with short intervals of high intensity. Your FDF Rowing Ergometer allows for changes
'on the fly', to achieve multi-level resistance profiles during a single workout. For more information on
exercise routines, please visit our website at www.firstdegreefitness.com
Adjustable Resistance (AR) Tank
Operation Instructions
WARNING
Do not overfill the tank
beyond the maximum
indicated level of 17
liters. Refer to the
tank level decal on the
lower side of the tank.
REQUIRED
Siphon [17]
CAUTION
Resistance adjuster
must be set to LEVEL 4
to allow for accurate
filling capacity.
Tank Filling and Water Treatment Procedures
a) Remove rubber fill plug from the top of the tank.
b) Place a large bucket of water next to the rower. Position the Siphon[17]
with rigid hose in the bucket, and flexible hose in the tank.
Note: Make sure small breather valve on siphon is closed before filling.
c) Squeeze siphon to begin filling. Important: Do not overfill tank
d) When full, open the valve on the top of the siphon to allow excess water to
escape.
e) Once filling is completed follow the water treatment schedule below, then
replace the tank plug.
CAUTION
In areas where tap
water quality is
known to be poor, FDF
recommends the use of
distilled water.
LEVEL 1: This setting keeps a portion of the water in reserve creating light
resistance
LEVEL 4 : This setting allows the maximum amount of water to reach the
flywheel for heaviest resistance
Siphon
Tank Plug
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for First Degree Viking 3 Plus 2019 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of First Degree Viking 3 Plus 2019 in the language / languages: English as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info