BASIC OPERATION
RECORDING
Motion Detection Setup
Motion detection is configurable on each channel. Configure motion
detection as follows:
1. Right click and select Setting click DEVICE. Then click MOTION DETECT.
This will bring up the Motion Detection Main screen.
2. Use the drop down box to select the channel to configure.
3. Click the ENABLE MD checkbox to activate the motion detection on this
channel.
4. Click on SET MD to reach the Motion Detection Sensitivity Screen which
allows the setting of the sensitivity level of detection.
5. Set the sensitivity by clicking within the Sensitivity
+ - rectangle to the appropriate level desired.
6. Click OK on the MD SETUP screen and then OK again
on the MOTION DETECT screen to confirm.
7. By default, any motion with the entire camera view will activate motion
detection. The DVR system will allow you to limit motion detection
within the camera area as desired. To choose an area to enabling
motion detection, place the cursor inside the camera view of the
Motion Detection Sensitivity Screen. Drag and click over the area
you want motion to be detected. A green rectangle is formed. Up
to four areas can be created. The result is that the area within any
of the green rectangles will detect motion. Click OK to confirm.
Motion Detection Alarm Settings
Motion detection can trigger recordings, buzzer alarms, an alarm output
control signal, and a preset position on a connected PTZ camera –
(purchased separately.) To set Motion Detection alarms do the following:
1. Click SET ALARM in the Motion Detect screen.
The ALARM SETTING screen will appear.
2. Alarm Duration: Input the duration of the alarm
in number of seconds. (1 – 9999999)
3. Buzzer: Place check mark in box if you want a
buzzer to sound locally from the DVR.
4. Client: Send message to client.
5. Record: Allows the selection of which camera records based off
motion detection. For instance, motion detected from camera channel
1 can activate motion on any of the other camera channels (1-16.)
6. Alarm Output: Place check mark in box if you want to send an
output control signal to a connected device. The device must
be connected to the output terminal on the alarm block on the
rear panel of the DVR. The control signal provided is 24 Vdc.
7. Preset: Place check mark in box to control a connected PTZ
camera to a PRESET position, such as an entry door or cash
box. Make sure the PTZ camera is connected to the channel
selected. Input the correct preset location as desired.
CCTV Resolution
CCTV resolution is measured in vertical and horizontal pixel dimensions and typically
limited by the capabilities of both the camera and the recorder that you are using for your
CCTV surveillance installation. CCTV systems use an analog video signal. For television
specifications (which CCTV uses) the highest resolution that can be captured and stored
is 704 x 480 (NTSC for the United States) and 720 x 576 (PAL for Europe). This resolution is known as D1
resolution. A high end CCTV recorder is capable of recording at up to D1 resolution.
CCTV Resolutions
D1: 704 x 480
HD1 (2CIF): 704 x 240
CIF: 352 x 240
QCIF: 176 x 120
Motion Detection Main Screen
Motion Detection Sensitivity Screen
Indicates motion record is enabled.
Indicates motion detected.
Alarm Setting Screen
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for First Alert PRO16810-600CA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of First Alert PRO16810-600CA in the language / languages: English as an attachment in your email.

The manual is 2.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info