DANGER: If any unit in the series does not alarm, TURN OFF POWER and recheck connections.
RESTORE POWER. If any unit within interconnected alarms does not alarm, replace it immediately.
Stand-Alone Alarm Only:
If you are only installing one smoke alarm, restore power to the junction box.
Interconnected Units Only:
If you are interconnecting multiple smoke alarms, repeat steps 1-5 for each smoke alarm in the series.
When you are finished, restore power to the junction box.
Step 1 Connect the power connector to the First Alert® alarm.
Step 2 Check all connections. Make sure all plugs are completely connected and snapped together.
Ensure the Adapter Plug is securely connected to the existing Power Connector.
NOTE: If you need to remove the power connector, turn POWER OFFrst. Insert a flat screwdriver blade between the
power connector and the security tab inside the power input block. Gently pry back the tab and pull the connector free.
Step 3 Line up the tabs on the unit with the notches on the mounting bracket.
Step 4 Install the base of the alarm to the mounting bracket, apply firm pressure, and turn clockwise
until a single, non-repeating audible chirp is heard.
Step 5 Restore power to the junction box.
NOTE: After you activate the alarm for the first time, the Color Indicator Ring will power up and the alarm
will welcome you. To program your alarm, follow the instructions provided in the Onelink Home App.
Step 6 Test each alarm. Press and hold the test button until the unit alarms. When testing a series of interconnected
units you must test each unit individually. Make sure all units alarm when each one is tested.
NOTE: Removing the alarm from the mounting bracket will turn the alarm o.
Setup & Installation (Continued)
Installing Onelink Safe & Sound
!
IM P ORTANT: If your alarm is not fully axed to the mounting bracket the alarm will produce
a repeating audible chirp.
Visit www.firstalert.com/product/safe-sound to view alarms compatible with Onelink Safe & Sound.
Interconnected Units Must Meet All of the Following Requirements:
A maximum of 12 compatible units may be interconnected (Maximum of 12 smoke alarms).
The same fuse or circuit breaker must power all interconnected units.
The total length of wire interconnecting the units should be less than 1000 feet (300 meters).
This type of wire is commonly available at Hardware and Electrical Supply stores.
All wiring must conform to all local electrical codes and NFPA 70 (NEC). Refer to NFPA 72,
NFPA 101, and/or your local building code for further connection requirements.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for First Alert 1039102 - Onelink at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of First Alert 1039102 - Onelink in the language / languages: English as an attachment in your email.

The manual is 2.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info