Cod. 710.056.02.00 – Rev. 04 – 07.06.2001
ENGLISH
page 14 of 63
1. GENERAL INFORMATION
1.1 FUNCTIONAL DESCRIPTION
Drying systems with refrigeration cycle have been designed for a cost effective elimination, with minimal overall
dimensions, of the condensate contained in compressed air by cooling it down to approximately + 3°C.
The operation principle of the dryers described in this manual is shown in the air and refrigeration circuit diagrams
(attachment A).
The air delivered to the services is virtually humidity free, and the condensate collected in the separator is discharged
through appropriate draining devices. In order to limit the size of the machine and to avoid condensation on the
external surface of the tubing, before exiting the dryer, treated air is counter current pre-heated by the air entering the
system.
The dryer comes provided with all the control, safety and adjustment devices, therefore no auxiliary
devices are needed.
A system overload not exceeding the maximum operative limits can worsen the operational performances of
the dryer (high dew point), but it will not affect its safety.
The electric diagram (attachment B) shows the minimum protection degree IP 42. The user must provide
the dryer with a line protection and a ground terminal.
1.2 USE OF THE MACHINE IN SAFE CONDITIONS
This system has been designed and manufactured in compliance with the European safety directive in force, therefore
any installation, use and maintenance operations must be performed respecting the instructions contained in this
manual.
Any installation, use and maintenance operation requiring to access the internal parts of the dryer must be
performed by qualified personnel.
The manufacturer will not be liable in case of uses different or nor complying with those foreseen in this
manual.
2. INSTALLATION
2.1 ACCEPTANCE AND TRANSPORTATION
At the moment the customer accepts the delivery, he must fully inspect the dryer to verify its integrity and the presence
of all the items listed in the shipping documentation.
Eventual claims for missing and/or damaged parts must be addressed directly to our facility or to the closest
reseller, within 8 (eight) days from the date on which the goods have been received.
It is mandatory to keep the dryer always in vertical position, as indicated by the symbols present on the packaging. For
eventual displacements, use devices having sufficient capacity for the weight of the machine.
Remove the packaging after having positioned the dryer in the installation site. We suggest to keep the original
packaging at list for the duration period of the warranty of the machine. Anyhow, do not forget to dispose the various
materials in compliance with the relevant rules locally in force.
If not in use, the dryer can be stored in its packaging in a dust free and protected site at a maximum temperature of 50
°C, and a specific humidity non exceeding the 90 %. Should the stocking time exceed 12 months, please contact the
manufacturer.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Finicompressors Artic 134-12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Finicompressors Artic 134-12 in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Finicompressors Artic 134-12

Finicompressors Artic 134-12 User Manual - German - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info