EnergyTop B80 / EnergyTop B125 / EnergyTop B160 / EnergyTop B250
Nr.
PARAMETERMENU Geadviseerde instellingen Alternatief instelbaar: Ingestelde waarde:
P01 Instelling cv-drukmeting .......................................... 00 = cv-druksensor ........... 01 (niet instellen) ................................................
P02 Afstemming van de print op toesteltype ................ 01 (moet 01 zijn) ................ 1-6 Zie blz. 15 en 16 .........
P03 Minimum toerental ventilator ................................... 01 (=50Hz) ........................ 0-255 (4 = 65)Hz .....................................
P04 Ontsteekniveau (in percentage van maximum) ..... 40 % .................................. 0-100 %
..................................................................................................
P05 Ventilatortoerental tijdens standby ......................... 00 Hz ................................. 0-255 Hz .........................................................
P06 Instelling blokkeren zomerstand ............................. - - ..................................... - - (niet instellen) ........................................
P07 Cv-stijgingslijn (cv-aanvoertemperatuur) .............. 02
o
C .................................. 1-10
o
C ..........................................................
P08 Minimum startpunt cv-stijgingslijn ........................... 20
o
C .................................. 20-80
o
C ..........................................................
P09 Nadraaitijd pomp (na vraag kamerthermostaat) ..... 15 minuten ......................... 0-255 minuten .................................................
P 10 Wachttijd na cv-gebruik (voor cv) ......................... 04 minuten ......................... 0-10 minuten .................................................
P11 Begrenzing capaciteitsinstelling voor cv ............... 100 % .................................. 0-100 % ..........................................................
P12 Instelling tijdelijk/continu nadraaien cv-pomp .......... 00 ( = zie parameter 09) ..... 01 = continu nadraaien ......................................
P13 Maximum toerental modulerende pomp (n.v.t.) ...... 100 % .................................. n.v.t. ..............................................................
P14 Temperatuur pompstop tijdens nadraaien (aanvoer) . 20
o
C ..................................... 0-100
o
C ..........................................................
P15 Begrenzing maximale instelling cv-setpoint ........... 90
o
C .................................. 20-90
o
C ..........................................................
P 16 Nadraaitijd pomp (na tapwatervraag) .................... 30 seconden ..................... 0-255 seconden ..............................................
P17 Wachttijd na tapwatervraag (voor cv) (“d1”) ........ 120 seconden ..................... 0-255 seconden ..............................................
P18 Maximaal vermogen voor tapwaterbereiding ........ 100 % .................................. 0-100 % ..........................................................
P 19 Begrenzing maximale instelling tapwatersetpoint .. - -
o
C .................................. - - (niet instellen) ........................................
P20 Min. warmhoudtemperatuur cv-wisselaar ............ - -
o
C .................................. - - (niet instellen) ........................................
(in comfortstand)
P21 dT cv-wisselaar in comfortstand .......................... - -
o
C .................................. - - (niet instellen) ........................................
P 22 Pompregel-dT aanvoer- en retoursensor (n.v.t.) ... 30
o
C .................................. 0-60
o
C ..........................................................
P 23 Max. dT tussen aanvoer- en retoursensor ........... 30
o
C .................................. 0-60
o
C ..........................................................
(regeling brander)
P24 Instelling laagste uitschakeldruk cv-druksensor .... - - ..................................... - - (niet instellen) ........................................
P25 Niet van toepassing ............................................... - - ..................................... - - (niet instellen) ........................................
P26 Niet van toepassing ............................................... - - ..................................... - - (niet instellen) ........................................
P27 Niet van toepassing ............................................... 00 ..................................... 01 ..............................................................
P 28 Instelling t.b.v. 230V voedingsfrequentie ............... - - = 50Hz .......................... - - (niet instellen) ........................................
Nr. Parameter-functie: Instellingen Alternatief instelbaar: Ingestelde waarde:
P01 CV-vraag aansturing ............................................. 0 (aan/uit-regeling) .......... 1 = OpenTherm WA
............................................................................... ..................................... 2 = 0-10Vdc temperatuur-aansturing
............................................................................... ..................................... 3 = 0-10Vdc vermogens-aansturing ....................
P02 CV-cascadesensor selectie .................................. 0 (uit) ............................... 1 (aan) ..............................................................
P03 Boiler-selectie ........................................................ 0 (aan) ............................. 1 (uit) ..............................................................
P04 Tijd-instelling driewegklep ...................................... 0 (seconden) ................... ..............................................................
P05 Cascade wachttijd (seconden) ............................. 0 (seconden) ................... ..............................................................
P06 Cascade wachttijd (minuten) ................................. 1 (minuten) ...................... ..............................................................
P07 Cascade niveau -toevoeging ................................. 15 (%) ............................... ..............................................................
P08 Cascade afval-niveau (in %) ................................. 5 (%) ............................... ..............................................................
P09 Open verdeler selectie .......................................... 0 (niet aanwezig) ............ 1 (aanwezig) .......................................................
P 10 Selectie water bijvullen .......................................... 0 (uit) ............................... 1 (aan) ..............................................................
P 11 Driewegklep lokatie selectie .................................. 0 (intern) .......................... 1 (extern) .............................................................
P12 0-10Vdc CV-uit temperatuur-regeling .................... 25 (Volt/10) ........................ ..............................................................
P13 0-10Vdc CV-aan temperatuur-regeling ................. 30 (V olt/10) ........................ ..............................................................
P 14 0-10Vdc max. voltage temperatuur-regeling ......... 100 (Volt/10) ........................ ..............................................................
P 15 0-10Vdc min. temperatuur-regeling ....................... 20 (
o
C) ............................... ..............................................................
P 16 0-10Vdc max. temperatuur-regeling ...................... 90 (
o
C) ............................... ..............................................................
P17 0-10Vdc CV-uit output-regeling ............................. 25 (Volt/10) ........................ ..............................................................
P18 0-10Vdc CV-aan output-regeling ........................... 30 (Volt/10) ........................ ..............................................................
P 19 0-10Vdc max. voltage output-regeling .................. 100 (V olt/10) ........................ ..............................................................
P20 0-10Vdc min. output output-regeling ..................... 0 (%) ............................... ..............................................................
P 21 0-10Vdc max. output output-regeling .................... 100 (%) ............................... ..............................................................
3.5 SYSTEEM-menu
Druk 10 seconden op de zomer-/ wintertoets .
Het SYSTEEM-menu is nu actief.
Druk op de LINKER
of en doorloop het
SYSTEEM-menu tot de te wijzigen parameter.
Wijzig evt. met de RECHTER en de waarde.
De ingestelde waarde wordt direct opgeslagen
Druk de zomer- /wintertoets
in om terug te keren
naar het SYSTEEM-menu. Druk 10 sec. op de zomer- /
wintertoets
om uit het SYSTEEM-menu te gaan.
Onderstaande PARAMETER-menu is een deel van het SERVICE-menu
0-10Vdc input Setpoint (
o
C) Vermogen (%)
(bij P02 = 2) (bij P02 = 3)
00 00
o
C Brander UIT
01 00
o
C Brander UIT
02 00
o
C Brander UIT
03 20
o
C Brander AAN: 035%
04 33
o
C Brander AAN: 044%
05 43
o
C Brander AAN: 054%
06 53
o
C Brander AAN: 064%
07 63
o
C Brander AAN: 073%
08 73
o
C Brander AAN: 083%
09 83
o
C Brander AAN: 093%
10 90
o
C Brander AAN: 100%
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferroli EnergyTop B125 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferroli EnergyTop B125 in the language / languages: Dutch as an attachment in your email.

The manual is 1,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ferroli EnergyTop B125

Ferroli EnergyTop B125 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info