1. Machine data
2. Safety instructions
3. Assembly
4. Use
5. Service & maintenance
1. MACHINE DATA
CONTENTS OF PACKING
1 Detail sander
5 Sandpaper
1 Dust bag
1 User manual
1 Warranty card
1 Safety instructions
INTRODUCTION
The Detail sander FDS-220 is designed for dry sanding of
surfaces of wood, plastic and filler as well as for painter
surfaces. It is particularly suitable for working on
profiles, in corners or hard-to-reach areas.
TECHNICAL SPECIFICATION
FEATURES
Fig. 1
1. On/off switch
2. Handle
3. Dust bag
4. Ventilating apertures
5. Sandpaper
6. Sanding-sole
2. SAFETY INSTRUCTIONS
EXPLANATION OF SYMBOLS
In this manual and/or on the machine the following
symbols are used:
In accordance with essential applicable safety
standards of European directives
Class II machine – Double insulation – You don’t
need any earthed plug.
Risk of damaging material and/or physical injuries
Shows presence of voltage
Faulty and/or discarded electrical or electronic
apparatus have to be collected at the appropriate
recycling locations.
ELECTRICAL SAFETY
Always check that the power supply corresponds to
the voltage on the rating plate.
Immediately throw away old cables or plugs when
they have been replaced by new ones. It is dangerous
to insert the plug of a loose cable in the wall outlet.
Only use an approved extension cable suitable for
the power input of the machine. The minimum
conductor size is 1,5 mm2. When using a cable reel
always unwind the reel completely.
SPECIFIC SAFETY INSTRUCTIONS
Contact or inhalation of dust coming free during
sanding (e.g. lead painted surfaces, woods and
metals), can endanger the health of operator and
bystanders. Always wear appropriate personal
equipment as a dust mask and use the dust bag during
sanding.
Check that the switch is not in the “ON” position
before connecting the machine to the mains voltage.
Always keep away the mains lead from moving parts
of the machine.
Use safety glasses, especially when sanding above
your head.
3. ASSEMBLY
DUST COLLECTION
Fig. 2
The sander has been carried out with a dust bag (3) to
keep the working surface clean. The dust bag must be
installed on the back side of the machine, on the opening.
It is necessary to empty the dust bag regularly for an
efficient use.
Empty it as follows:
Turn the dust bag slightly and pull it out of the
machine’s adapter.
Empty the dust bag in a suitable place.
Push the dust bag on to the machine’s adapter till it
locks into place.
Remember that the dust extraction only works
when using perforated sandpaper.
Voltage | 230 V~
Frequency | 50 Hz
Input power | 220 W
Tool class | II
No load speed | 13000/min
Weight | 1.25 kg
Lpa (Sound pressure level) | 76.0 dB(A)
Lwa (Sound power level) | 87.0 dB(A)
Vibration | 1.24 m/s2
Ferm 3
SPARE PARTS LIST FDS-220
REF NR DESCRIPTION FERM NR
408225 CARBON BRUSH (SET) 3
408228 LONG SUPPORT BAR 12
408226 SAND SOLE 15
408255 SHORT SUPPORT BAR 20
408227 SWITCH + COVER 21+22
408257 DUST BAG 30
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm r. PSM1017 FDS-220 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm r. PSM1017 FDS-220 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info