763660
7
Zoom out
Zoom in
Previous page
1/20
Next page
7
EN
Warning! This unit is to be used with a
cold-water source only!
Turn on the pressure washer, once all the air
has been expelled and water has reached the
end of the lance.
Electrical Cables
Ensure that all cables are damage free before
connecting to the power supply.
Plug in the pressure washer and turn the unit
on with the main switch (2).
4. USE
CAUTION! The cleaner must only be
used with clean water; use of unfiltered
water or corrosive chemicals will damage
the cleaner.
Turn the motor switch to the “0” position.
Check that the electrical supply voltage and
frequency (Volts/Hz) correspond to those
specified on the cleaner data plate.
If the power supply is correct, you may now
plug in the cleaner.
The electric supply connection shall be made
by a qualified electrician. It is recommended
that the electric supply to this appliance
should include either a residual current device
that will interrupt the supply if the leakage
current to earth exceeds 30 mA for 30 ms or a
device which will prove the earth circuit.
CAUTION! The machine may cause
electrical disturbances when starting.
If the motor stops and fails to restart, wait 2-3
minutes before restarting. THERMAL CUTOUT
TRIPPED
Adjusting the nozzle
Fig. 2
Water may be sprayed out of the nozzle either
linearly or in a fan shape. Turn on the pressure
first, and then adjust the nozzle.
Water inlet filter
The water inlet filter must be inspected regu-
larly, so as to avoid blockage and restriction of
the water supply to the pump.
CAUTION! Never disconnect the high-
pressure hose from the machine while
the system is still pressurized.
5. SERVICE & MAINTENANCE
Warning! Unplug the electric cable
(power source) prior to any maintenance
or preparatory storage operations.
Make sure that the machine is not live when
carrying out maintenance work on the motor.
To ensure good performance, check and clean
the suction and detergent filters after every 50
hours of operation.
Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
1. When switched on, the machine will not
start working.
Plug is not well connected or electric socket is
faulty.
Check plug, socket and fuse.
The mains voltage is lower than the minimum
requirement for start up.
Check that the mains voltage is adequate.
The pump is stuck.
Refer to after storage instructions. Switch
off the unit and let the motor cool.
Thermal safety has tripped.
Leave the lance open with water coming
through.
2. Fluctuating pressure
Pump sucking air
Check that hoses and connections are
airtight
Valves dirty, worn out or stuck. Pump seals worn.
Clean and replace or refer to dealer.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm GRM1022 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm GRM1022 in the language / languages: English as an attachment in your email.

The manual is 3,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ferm GRM1022

Ferm GRM1022 User Manual - English, German, Dutch, French, Italian, Polish, Portuguese, Finnish - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info