water to run on to unwashed surfaces.
Shutting down the pressure washer
The use of detergents can dramatically reduce
cleaning time and assist in the removal of difficult
stains. Some detergents have been customized
for pressure washer use on specific cleaning
tasks. These detergents are approximately as
thick as water. The use of thicker detergents,
such as dish soap, will clog the chemical
injection system and prevent the application of
the detergent. The cleaning power of detergents
comes from applying them to a surface and
giving the chemicals time to break down the dirt
and grime. Detergents work best when applied
at low pressure. The combination of chemical
action and high pressure rinsing is very effective.
On vertical surfaces, apply the detergent starting
at the bottom and work your way upward. This
will prevent the detergent from sliding down and
causing streaks. High pressure rinsing should also
progress from the bottom to top. On particularly
tough stains, it may be necessary to use a brush
in combination with detergents and high pressure
rinsing.
CAUTION! Never disconnect the high-
pressure hose from the machine while
the system is still pressurized.
Follow the correct procedure:
1. Turn off the pressure washer by using the
switch on the machine.
2. Unplug the unit from the power source.
3. Turn off the water supply at the tap.
4. Press the trigger of the gun to depressurize the
system.
5. Disconnect the supply hose to the machine
6. Wipe all surfaces of the unit with a damp clean
cloth.
7. Engage the safety lock.
5. SERVICE & MAINTENANCE
Warning! Unplug the electric cable
(power source) prior to any maintenance
or preparatory storage operations.
Make sure that the machine is not live when
carrying out maintenance work on the motor.
To ensure good performance, check and clean
the suction and detergent filters after every 50
hours of operation.
Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
1. When switched on, the machine will not
start working.
Plug is not well connected or electric socket is
faulty.
Check plug, socket and fuse.
The mains voltage is lower than the minimum
requirement for start up.
Check that the mains voltage is adequate.
The pump is stuck.
Refer to after storage instructions. Switch
off the unit and let the motor cool.
Thermal safety has tripped.
Leave the lance open with water coming
through.
2. Fluctuating pressure
Pump sucking air
Check that hoses and connections are
airtight
Valves dirty, worn out or stuck. Pump seals worn.
Clean and replace or refer to dealer.
3. Water leaking from the pump
Seals worn out
Check and replace, or refer to dealer
4. The motor stops suddenly
Thermal safety switch has tripped due to
overheating.
Check that the mains voltage corresponds
to specifications. An extension cable,
which is too thin, and tool long can cause
a voltage drop and cause the motor to
overheat. Leave to cool down. Use heavy
duty extension cables.
5. The pump does not reach the necessary
pressure.
Water inlet, filter is clogged
Clean the water inlet filter
Pump sucking air from connections or hoses
Check that all supply connections are tight
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm GRM1013 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm GRM1013 in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info