Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
1. When switched on, the machine will not
start working.
• Plug is not well connected or electric socket is
faulty.
• Check plug, socket and fuse.
• The mains voltage is lower than the minimum
requirement for start up.
• Check that the mains voltage is adequate.
• The pump is stuck.
• Refer to after storage instructions. Switch
off the unit and let the motor cool.
• Thermal safety has tripped.
• Leave the lance open with water coming
through.
2. Fluctuating pressure
• Pump sucking air
• Check that hoses and connections are
airtight
• Valves dirty, worn out or stuck. Pump seals
worn.
• Clean and replace or refer to dealer.
3. Water leaking from the pump
• Seals worn out
• Check and replace, or refer to dealer
4. The motor stops suddenly
• Thermal safety switch has tripped due to
overheating.
• Check that the mains voltage corresponds
to specifications. An extension cable, which
is too thin, and tool long can cause a
voltage drop and cause the motor to
overheat. Leave to cool down. Use heavy
duty extension cables.
5. The pump does not reach the necessary
pressure.
• Water inlet, filter is clogged
• Clean the water inlet filter
• Pump sucking air from connections or hoses
• Check that all supply connections are tight
• Suction/ delivery valves are clogged or worn
out.
• Check that the water feeding hose is not
leaking.
• Unloader valve is stuck
• Clear or respire valves
• Lance nozzle incorrect or worn out
• Loosen and re-tighten regulation screw
Check and/ or replace.
Repairs and servicing should only be
carried out by a qualified technician or
service firm.
Cleaning
Keep the ventilation slots of the machine clean to
prevent overheating of the engine.
Clean the housing regularly with a soft cloth,
preferably every time it is used.
Keep the air vents free f dust and dirt. Remove
stubborn dirt with a soft rag moistened in soapy
water. Do not use any solvents such as petrol,
alcohol, ammonia, etc. as such substances can
damage the plastic parts.
Lubrication
The appliance does not need any extra lubrication.
Storage and transportation
Keep the high pressure washer in well-ventilated
dry premises with temperature not going below
+5ºC. Operate the cleaner with non-corrosive/non-
toxic antifreeze before storing for the winter.
Faults
If a fault arises through wear in an element, please
contact the service address shown on the
warranty card. A drawing of the spare parts that
may be obtained is included at the end of these
operating instructions.
Environment
To prevent damage during transport, the appliance
is delivered in a solid packaging which consists
largely of reusable material. Therefore please
make use of options for recycling the packaging.
Damaged and/or disposed of electrical
or electronic devices must be dropped
off at recycling stations intended for that
purpose.
Warranty
Read the terms of warranty on the separate
warranty card which is enclosed.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm GRM1010 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm GRM1010 in the language / languages: English as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info