Vi erklærer herved, udelukkende på eget ansvar, at dette
produkt opfylder følgende standarder eller
standardiserede dokumenter
EN60335-1
EN60335-2-79: 1998
i overensstemmelse med direktiverne:
98/37/EØF
73/23/EØF
89/336/EØF
fra 01-11-2004
ZWOLLE NL
W. Kamphof
Quality department
CE
ı
KONFORMITETSERKLÆRING
(
DK
)
Ferm 57
be of an approved waterproof type for outdoor use
and marked accordingly. Extension cables must be
threecore, one of which is EARTH.
SWITCH OFF THE MACHINE IMMEDIATELY
IN CASE OF
1. Malfunction in the mains plug, power cable or
damaging of cable.
2. Broken switch.
3. Smoke or stench of scorched insulation.
SPECIFIC SAFETY RULES
The USE and MAINTENANCE manual constitutes an
essential part of the cleaner equipment and should be
kept in a safe place for future reference. If you sell the
cleaner, the manual should be handed on to the new
owner.
- Before starting the cleaner, make sure that it is
receiving water correctly. Operating the cleaner
without water could damage the seals.
- Do not disconnect the plug by pulling on the
electrical cable.
- If you are too far from the object you wish to clean,
do not move the cleaner nearer by pulling on the high
pressure hose; use the handle provided.
- In versions not equipped with AMS device, do not
operate the cleaner for more than 1-2 minutes with
the gun closed as this could damage the seals.
- Protect the cleaner from freezing during the winter.
- Do not obstruct the ventilation grilles during
operation.
- The cross-section of any extension cables used must
be proportional to their length, i.e. the longer the
extension cable, the greater the cross-section;
cables with a protection level of "IPX5" must be used.
- Position the cleaner AS NEAR POSSIBLE to the
water supply.
- The packaging is easily recyclable, and must be
disposed of in compliance with the regulations in
force in the country of installation.
- Use the cleaner only with accessories and
replacement parts authorized by the manufacturer.
The use of original accessories and replacement
parts will ensure safe, trouble-free operation.
- The cleaner must be used standing on a secure, stable
surface.
- Avoid unintentional firing of the trigger. Do not carry
the lance/ trigger assembly with your hand over the
trigger. Always use the trigger lock mechanism.
- Ensure that the safety lock on the trigger is used,
when you have stopped using the pressure washer to
prevent accidental operation. (Fig. 5)
SAFETY "MUST NOTS"
- EXPLOSION OR POISONING.
DO NOT use the cleaner with inflammable or toxic
liquids, or any products which are not compatible
with the correct operation of the cleaner.
- INJURY HAZARD.
DO NOT direct the water jet towards people or
animals.
- ELECTRIC SHOCK HAZARD.
DO NOT direct the water jet towards the unit itself,
electrical parts or towards other electrical
equipment.
- SHORT CIRCUIT HAZARD.
DO NOT use the cleaner outdoors in case of rain.
- INJURY HAZARD.
DO NOT allow children or incompetent persons to
use the cleaner.
- ELECTRIC SHOCK HAZARD.
DO NOT touch the plug and/or socket with wet
hands.
- ELECTRIC SHOCK AND SHORT CIRCUIT
HAZARD.
DO NOT use the cleaner if the electrical cable is
damaged.
- EXPLOSION HAZARD.
DO NOT use the cleaner if the high pressure hose is
damaged.
- ACCIDENT HAZARD.
DO NOT jam the trigger in the operating position.
- ACCIDENT HAZARD.
Check that the data plates are affixed to the cleaner,
if not, inform your dealer. Cleaners without plates
must NOT be used as they are unidentifiable and
potentially dangerous.
- EXPLOSION HAZARD.
DO NOT tamper with or with or alter the
calibration of the safety valve.
- HAZARDOUS ALTERATION OF OPERATING
PERFORMANCE.
DO NOT alter the original diameter of the spray
head nozzle.
- ACCIDENT HAZARD.
DO NOT leave the cleaner unattended.
- SHORT CIRCUIT HAZARD. DO NOT move the
cleaner by pulling on the electrical cable.
SAFETY "MUSTS"
- SHORT CIRCUIT HAZARD.
All electrical conductors MUST BE PROTECTED
against the water jet.
- ELECTRIC SHOCK HAZARD.
The cleaner MUST ONLY BE CONNECTED to a
correctly earthed power supply.
- Use a Residual Current Device (RCD) of not more
than 30 mA, at the plug socket when using this
appliance.
- INJURY HAZARD.
The high pressure may cause materials to bounce off
surfaces at speed; therefore protective clothing and
safety goggles MUST BE WORN.
- ACCIDENTAL START-UP HAZARD.
Before doing work on the cleaner, REMOVE the
plug.
- INJURY HAZARD.
Before pressing the trigger, GRIP the gun firmly to
counteract the recoil.
- CONTAMINATION HAZARD.
COMPLY WITH the requirements of the local water
supply company. According to DIN 1988, power-jet
cleaners may only be connected to the mains
drinking water supply if a backflow preventer valve
with drain facility is installed in the supply hose.
- ACCIDENT HAZARD.
Maintenance and/or repair of electrical components
4 Ferm
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm GRM1006 - FHPW 160 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm GRM1006 - FHPW 160 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 3,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info