OPERATING INSTRUCTIONS
Automatic Operation
When the pump is lowered into the water and the power
is switched on, it will start to operate as soon as the flo-
ating switch reaches the minimum activation height in the
water.
Remember: The pump must be carried by, and placed
in the water using the carry handle or if the water is deep,
be lowered on a rope tied to the carry handle.
Manual Operation
Where manual operation is preferred, the motor can be
activated by raising the floating switch by hand (ON) or
lowering it by hand (OFF).
Ensure the distance between the float switch and
the latch holder is not to small as to restrict the up
and down movement of the float switch.
We declare under our sole responsibility that this
product is in conformity with the following standards
or standardized documents
EN 60335-1, EN 60335-2-41, EN 55014-1, EN
55014-2, EN 61000-3-3, EN61000-3-3.
in accordance with the regulations.
98/37/EEC,
73/23/EEC,
89/336/EEC
from 01-01-2004
ZWOLLE NL
W. Kamphof
Quality department
It is our policy to continuously improve our products and
we therefore reserve the right to change the product
specification without prior notice.
Ferm B.V. Zwolle, The Netherlands
CE
ı
DECLARATION OF CONFORMITY
(
UK
)
Ferm 5
Problem Cause Remedy
Pump does not start No mains supply Check mains supply
Floater restricted Bring floater to higher position
Pump is active but
no water is being delivered Turbine Clogged Disconnect pump from the power
supply and clean or unblock the turbine
(see 'BLOCKAGES')
Pump will not switch off Floater restricted Bring floater to as lower position
Pump will not start or stops Thermal overload safety Disconnect from the power supply,
during use. Pump switched off switch has activated leave for 2 minutes and clear the
after short operating periods turbine (if required - see 'Blockages')
Power has tripped Check fuses and electrical connections
Turbine Clogged
Water too hot Ensure that the water temperature has
not exceeded the maximum of 35 C
TROUBLE SHOOTING GUIDE