EN
to the instructions represented in fig. 2. Place the
compressor on a flat surface or at a maximum slope
of10°(fig.3),inawellventilatedarea,protected
against atmospheric factors and not in explosive
surroundings.Ifthesurfaceareaisslopingand
smooth,makesurethatthecompressorwillnot
movewheninoperation.Ifthesurfaceareaisa
boardorashelfofabookcase,justmakesurethat
they cannot fall down by securing them properly.
Forproperventilationandeffectivecooling,itis
important that the compressor is positioned at least
100 cm from the wall (fig. 4).
Make sure that the compressor is
transported in the right way, do not turn it
upside down and don’t lift it with hooks
or ropes (fig. 5-6).
Filling the compressor with oil.
Your compressor is supplied with oil which is
already included in the carter.
Beforeuse,removethetransportcaponthecarter
(12),andreplaceitbytheregularoilcap(fig7).
Beforeuse,ensurethatoillevelissufficient.
This can be checked by checking the oil
inspectionglass(13).Whencompressorisplaced
horizontally,theoillevelshallreachtheredmark.
Installing the air filters.
Remove the transport lids and replace them with
the supplied air filters before using the compressor.
Starting up
• Checkwhetherthemainsvoltagecorresponds
to that indicated on the electrical specification
plate(fig.10),thepermittedtolerancerange
should be within 5%.
• Presstheswitch(3)situatedontheupperpart
intothe“0”positionaccordingtothepressure
regulator type fitted on the device (fig. 11).
• Puttheplugintheplugsocket(fig.9)andstart
the compressor up by putting the switch(3)
ofthepressureregulatorinthe“I”position.
The operation of the compressor is fully
automatic. The pressure regulator will stop
the compressor when the maximum value has
been reached and start it up when the pressure
drops below the minimum value. Normally
the difference in pressure is approx. 2 Bar/29
psi between the maximum and the minimum
value.Forinstance-Thecompressorwillstop
when it reaches 8 Bar (116 psi) (this is the
maximum operating pressure) and will start
up automatically when the pressure within the
tank has dropped to 6 Bar (87 psi).
The head/cylinder/transmission pipe
assembly may reach high temperatures,
so take care when working close to these
parts and do not touch them to avoid
burns (fig. 12 - 13).
Adjusting the operating pressure
Fig. 14
Itisnotnecessarycontinuouslytousethe
maximumoperatingpressure,thecompressed-air
toolsoftenrequirelesspressure.Withregardto
compressors supplied with a pressure reduction
valve it is necessary to set the operating pressure
properly.
Itispossibletosettheoperatingpressureby
using the turning knob(5) on the reduction valve.
• Byturningclockwise,thepressurewillbe
increased.
• Byturninganti-clockwise,thepressurewillbe
reduced.
The compressor has two pressure gauges and
onepointtoconnectanairhose:
• Pressuregauge(7):Thepressureofthisoutlet
can be regulated with help of the reduction
valve (5).
• Pressuregauge(8):tankpressure
Hintsforaccurateadjustmentofthepressure
regulation:
• Turntheturningknob(5)anti-clockwisetill
pressure is fully released
• Connecttheairtoolyouwanttousetothe
quick coupler (6)
• Activatetheairtoolshortly,sothepressure
gauge (7) will show the right pressure level
• Turntheturningknob(5)clockwise,tillthe
pressure gauge (7) shows the pressure level
you need
• Yourairtoolisnowreadytouse.
Note:whennotconnectinganairtoolwhile
adjustingthepressure,itmightoccurthepressure
gauge (7) is not reacting accurately on the
pressure drop.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1045 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1045 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 6,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info