c)
When battery pack is not in use, keep it away
from other metal objects, like paper clips,
coins, keys, nails, screws or other small metal
objects, that can make a connection from
one terminal to another. Shorting the battery
terminals together may cause burns or a fire.
d) Under abusive conditions, liquid may be
ejected from the battery; avoid contact.
If contact accidentally occurs, flush with
water. If liquid contacts eyes, additionally
seek medical help. Liquid ejected from the
battery may cause irritation or burns.
e) Integrated batteries may only be removed
for disposal by qualified personnel.
Service
a) Have your power tool serviced by a
qualified repair person using only identical
replacement parts. This will ensure that the
safety of the power tool is maintained.
For the charger
Intended use
Charge only 3.6V max.1.3Ah Li-ion type
rechargeable battery packs. Other types of batteries
may burst causing personal injury and damage.
a) The appliance is not to be used by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they
have been given supervision or instruction
b) Children being supervised not to play with
the appliance
c) Do not recharging non-rechargeable batteries!
d) During charging, batteries must be placed in
the well ventilated area!
Residual risks
Even when the power tool is used as
prescribed it is not possible to eliminate all
residual risk factors. The following hazards
may arise in connection with the power tool’s
construction and design:
a) Health defects resulting from vibration
emission if the power tool is being used
over longer period of time or not adequately
managed and properly maintained.
b) Injuries and damage to property to due to
broken accessories that are suddenly dashed.
Warning! This power tool produces an
electromagnetic field during operation.
This field may under some circumstances
interfere with active or passive medical
implants. To reduce the risk of serious or
fatal injury, we recommend persons with
medical implants to consult their
physician and the medical implant
manufacturer before operating this
power tool.
2. MACHINE INFORMATION
Intended use
This screw driver is intended for driving in and
loosening screws
Technical specifications
Model No CDM1132
Charger CDA1102
Input of charger 100-240V~ 50/60Hz
Output of charger 5V DC 0.5A
Battery charging time 3-5 hours
Rechargeable battery cell 3.6V Li-ion 1300mAh
Chuck capacity ¼” hex
No load speed 230 /min
Sound pressure level LPA 54 dB(A) K= 3 dB(A)
Sound power level LWA 65 dB(A), K=3dB(A)
Hand-arm vibration ah
(screw driving without impact) 0.369 m/s2 K=1.5 m/s2
Vibration level
The vibration emission level stated in this
instruction manual has been measured in
accordance with a standardized test given in
EN 62841; it may be used to compare one tool
with another and as a preliminary assessment of
exposure to vibration when using the tool for the
applications mentioned.
Using the tool for different applications, or with
different or poorly maintained accessories,
may significantly increase the exposure level.
The times when the tool is switched off or
when it is running but not actually doing the
job, may significantly reduce the exposure
level.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CDM1132 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CDM1132 in the language / languages: All languages as an attachment in your email.

The manual is 14,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info