Always wear safety glasses and old
clothes during working with the battery ,
because battery acid is a biting product!
3. INSTALLATION
Before putting the battery charger into operation
thefollowingstepsneedtobetaken(Fig.1):
• If the battery is still connected, it needs to be
disconnected,
• first the negative terminal (A);
• then the positive terminal (B)!
It is advisable to remove the battery from the
vehicle before charging it.
• Check the level of the battery acid. For this
purpose remove the battery stoppers first,
then check the acid level and, if necessary, fill
upwithdistilledwater(availablefromthe
chemists’).Theleveloftheelectricchargecan
be checked with a hydrometer.
• Clean the connections and the terminals. This
can be done with a steel wire brush or with
sandpaper.
• Connect the positive clamp of the charger
(red)tothepositiveterminal(+)ofthebattery.
Then connect the negative clamp of the
charger(black)tothenegativeterminal(-)of
the battery.
• Check if the clamps of the charger are firmly
connected to the battery.
• The following steps need to be taken with the
help of the information of the charge control
display.
• (Caution!(1)Ourchargersareonlysuitablefor
those accumulators having a residual voltage
above 2 V - 4 V. No current flows into batteries
havingaresidualvoltagebelow2V-4V(2).
The current meter only provides a general
indicationandnotanexactmeasurement).
4. OPERATING THE BATTERY
CHARGER
The charging process starts after connecting the
clamps correctly to the battery and connecting the
plug to the mains. The charging current is visible
onthedisplayonthefrontFig.2).
• The charging process starts when the red light
comes on.
• The battery is fully charged when the green
light comes on.
Overload
When the charging current becomes too high the
red light will indicate that there is an overload and
the charging process will stop.
After cooling down, the charger will start
automaticallyagain(redlightgoesoutagain).
Reverse
The red light indicates that the battery charger is
not connected correctly to the battery: the clamps
havetobeexchanged(redclampon+andblack
clampon-).
Check charged battery
On the basis of the specific gravity of the battery
acid can be gathered if an battery is fully loaded
or not. With the help of a specific gravitymeter the
specific gravity can be appointed.
Empty battery: s.g. = 1.13 kg/dm
3
Full battery: s.g. = 1.28 kg/dm
3
5. MAINTENANCE
Always remove the plug from the mains socket
when the battery charger is being serviced or
cleaned. Never use any water or other liquids
when cleaning the charger. Keep the cable
and your battery charger clean. Some cleaners
andsolvents(petrol,thinner)canaffectordis-
solve plastic parts. These products contain
a.o. benzene, trichloroethylene, chloride and
ammonia.
Defective batteries
• Damaged batteries which do not retain their
charge. It is often the case that batteries which
are in very bad condition can no longer be
charged;theyneedtobereplacedbecause
they do not retain their charge.
• Short circuited batteries.
If, after several hours the battery charger still
does not indicate that the battery is being
charged, this usually means that one of the
elements is short circuited. The battery needs
to be replaced.
Malfunction
If your battery charger no longer functions as it
should, this may be due to the following reasons:
• The clamp has been connected wrongly.
Check if the right clamp is connected to the
right terminal.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm BCM1018 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm BCM1018 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info