Original operatin instructions in German
Wipe the top section with a damp cloth.
Allow the container and accessories to dry
2 Before use
When unpacking, check that the delivery is complete and that
there is no transport damage.
Before using, the operators should be provided with information,
instructions and training for the use of the vacuum cleaner
and the substances that it is to be used for, including the safe
procedure for the removal of the gathered material.
3 Only use original accessories
See enclosed sheet.
Further accessories are given in the special acessories list or
upon request.
4 Fields of application
For wet and dry suction cleaning. Not suitable for vacuuming
health hazardous dusts. The suction cleaner with socket and ON/
OFF automatic switching system is intended for the connection of
electric tools.
5 Assembly
When unpacking, check that the appliance is complete and that
there is no transport damage.
5.1 Container .
Open the lock-in closures of the 20-l and 32-l container, and
lift off the top section . Tip over the container and press in the
steering rollers with pivot until they lock into place. Screw the
large wheels onto the axles ; see g. A.
The supplied steel axle for the 45-l container is pushed through
the guide on the container, after which the wheels and steering
rollers are mounted as indicated in g. B.
The steering rollers for appliances with 22-l, 35-l and 55-l
stainless steel containers with chassis crosshead are mounted as
indicated in g. C.
Insert suction tube VCF32/1200; VCF45/1400 (when contai-
ned in scope of supply) into the container guide from above and
push down until it engages.
nsert suction tube VCF20/1000 (when contained in scope of
supply) into the container guide from above and push down until it
engages.
5.2 Filters -
Fitting the lters, depending upon the given model::
- Push the folded lter cartridge in a straight manner over
the case , right up to the stop point, and lock the bayonet
mount ; see g. D. The folded lter is suitable for wet and dry
suction cleaning.
- Foam lter
To suction the water, rst remove the folded lter; push the foam
lter over the casing , see Fig. E
- Take hold of the paper lter bag at the ang and push ver-
tically from above into the guide of the cyclone suction opening
until the stop point is reached. The bag must rest against the
container wall; see g. F.
For stainless steel containers, push the ange onto the suction
opening at the bottom rst and then at the top, then keep
pushing as far as it will go.
- The bag increases the dust retaining capacity and is
intended for hygienic disposal. Paper lter bags can only
be used for dry suction cleaning.
- Place the lter sack in the container respectively for
stainless steel containers slip over the edge of the container,
see g. G.
Remove the lter for wet suction cleaning.
5.3 Top section
From time to time, or when the suction force decreases, take out
the motor protection lter for cleaning; see g. I. Place the top
section right-way-round on the container as indicated in g. H.
Observe the anti-rotation protection. The paper lter bag must
not be damaged, and the lock-in closure must engage securely.
5.4 Socket with ON/OFF automatic switching system
For suction cleaners with socket and ON/OFF automatic switching
system.
The socket e is intended for the connection of electrical tools. In
the “0“ switch setting, the socket can be used as an extension line
(e.g. for a light).
Connected load: Suction unit and appliance max. 16 A
WARNING! An electric tool must be switched off when it is connec-
ted. The socket is always live when the plug is inserted in a mains
socket, irrespective of the switch position
The suction openings of electric tools are not standard.
Consequently, an adapter (Rubber sleeve) 547275 is available that
can be shortened to t the given electric tool.
For other suction connections contact your dealer or the manufac-
turer of the given electric tool.
5.5 Filter cleaning
Appliances tted with an electromagnetic cleaning device can
remove the dust adhering to the folded lter by vibration. This
ensures optimal use of the folded lter and extends the operating
cycles
VCF20/1000:
If the cleaner loses suction switch off the appliance (switch a on
position 0) and hold down the push button b for approx. 15 sec.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Felisatti VCF45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Felisatti VCF45 in the language / languages: English, German, French, Italian, Portuguese, Spanish, Finnish as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.