502503
5
Zoom out
Zoom in
Previous page
1/26
Next page
The flexible hoses of conventional vacuum cleaners fit
directly onto the dust extraction nozzle.
The aspirator should be suitable for the material being
worked.
A special aspirator must be employed in those cases
where dry harmful or carcinogenic dust is produced.
ACCESSORIES
Accessories and their corresponding order number can
be found in our catalogues.
MAINTENANCE AND CARE
WARNING! Always unplug the machine before carrying
out work on it.
- Inspect the tool: Using a worn out polishing or polish-
ing tool will reduce working efficiency.
- Inspect the mounting screws: Regularly inspect all
the mounting screws and ensure they are firmly tight-
ened. Should any screw be loose, tighten it immedi-
ately. Failure to do so could put you at serious risk.
- Motor maintenance: Always take the greatest care
over this and make sure that the motor winding is not
damaged and does not become wet with oil or water.
- The vents should always be kept clean and free of
obstacles.
- Clean the machine thoroughly after each use. Blast the
motor regularly with compressed air.
- Check that the mains lead is in good condition. If
it is not, take it to an Official Service Centre to
have it replaced.
- Brush replacement: The brushes should be replaced
after 150 - 200 hours use or when they are less than
10 mm long. Have this done by an Official Service
Centre. We recommend that at every second change
of brushes, you take the machine to one of our Official
Service Centres for general cleaning and oiling.
- Use only Felisatti accessories and spares. Parts the
changing of which is not covered in this instruction
manual, should be replaced in a Felisatti Official
Service Centre (See Warranty/Official Service Centre
address leaflet).
Do not dispose of electric tools in
the household waste!
In accordance with European Directive 2002/96/EC
relating to old electrical and electronic appliances and
its translation into national law, used electric tools must
be collected separately and recycled in an ecologically
desirable way.
WARRANTY
See general warranty conditions printed on the attached
sheet.
NOISE AND VIBRATION
This tool has been designed and made to reduce noise
to a minimum. However, in spite of this, in certain
circumstances the maximum noise level in the place
of work could exceed 85 dBA. In this case, the op-
erator should wear ear protection.
The machine's noise and vibration levels, measured in
compliance with EN60745-1, usually reach:
Acoustic pressure = 82 dB(A)
Sound-power level = 92 dB(A)
Use ear protection!
Vibration acceleration = 7.5 m/s
2
DECLARATION OF CONFORMITY
We hereby declare, under our sole responsibility,
that the FELISATTI brand products described in
this manual RGF150/600E comply with the
following standards or standard documents:
EN60745-1:2008, EN55014-1:2006+A1,
EN55014-2:1997+A1+A2, EN61000-3-
2:2006+A1+A2 and EN61000-3-3:2008 in accor-
dance with EU Directives 2006/42/EC,
2006/95/EC, 2004/108/EC and 2002/95/EC.
11
Francisco Ruiz
Plant Mgr.
We reserve the right to make technical changes 09/2001
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Felisatti RGF150 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Felisatti RGF150 in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info