The saw blade can be directly inserted into the material (only
for wood work pieces), but this operation should only be
performed by operators with considerable work experience
and with the exclusive use of short blades.
With the machine running, the saw blade should be rested on
theworkpieceatanangleof55°-60°(g.4)inrelationtothe
front edge of the base, it should then be pressed, slowly and
carefully, onto the material.
Therstphaseoftheoperationshouldbeundertakenwith
great care: sudden counter-strokes and overloads during
contact between the blade and work piece, or excessively
rapid penetration of the material, can provoke blade
breakage.
Penetration should only be carried out at maximum speed.
45° ANGLED CUTTING
The straight blade should always be tted for angled or
shapedcuttingoperations(Felisatti000.512.054type).
For circular cuts, use the overturned side cutting regulating
device, with the end bit positioned at the center of the circle
that is to be cut.
For 45° angled cuts to the right or to the left, incline the base
plate.
SIDE GUIDE
If cutting operations need to be carried out at a preset
distancefroma90°rabbet,thespecialsideguideL(Fig.1-2)
(suppliedwiththemachine)canbetted.
The guide should be inserted sideways into the base plate
housing.Inordertoxthedistancefromthedesirededge,
tightentheatheadscrewslocatedonthebase.
ANTI-SHAVINGS PLATE (g.5)
The plate should be inserted into the machine base from
below,asshownintheg.
During cutting operations, the wood bers willbe pressed
against the plate, thus avoiding tears and snags.
The use of the plate is limited to right angle cuts.
SHAVINGS SUCTION UNITS
In order to keep working areas clean and dust free, the
machinehasbeenttedwithasuctionpipeunion.
To carry out this operation, connect a corrugated pipe to this
union.
IMPROPER USE
The functions and use of this tool are those exclusively
indicated in this manual.
Any other use of the tool is explicitly forbidden!
MAINTENANCE
Regular inspection reduces the necessity for maintenance
operations and will keep your tool in good working condition.
The tool bearings and gears are life-long lubricated, however
it is advised to check the condition of the grease in the head
every 100 hours, if necessary replace the grease (use GR-
MU-EP2AGIPgrease,orasimilarproduct).Themotormust
be correctly ventilated during tool operation. For this reason
avoid blocking the air inlets with hands.
The movable needle on the blade support should be
periodically lubricated with a few drops of oil.
After use disconnect the tool from the power supply and
clean carefully.
DISPOSAL
At the end of the machine’s working life, or when it can no
longer be repaired, ensure that it is disposed of according
to the standard regulations of the country in which it is
being used, and that the disposal operation is carried out by
specialized personnel following authorized guidelines.
In all circumstances:
- Do not abandon in the environment;
- Do not dispose of together with solid urban waste
products;
- Contact the special recycling centers.
PARTS REPLACEMENT
Attention! Disconnect the plug from the power supply socket
before replacing any parts.
BRUSHES
The brushes must be replaced after approx. 150-200 working
hours, or if they are less then 5-6 mm in length.
Attention! For correct tool operation always change
the brushes in pairs, not separately. The use of original
Felisatti spare parts is recommended.
Giventhedifcultyofthisoperation,itisadvisedthatitshould
only be performed by an authorized service center.
ATTENTION: After tting new brushes allow the motor to
run idle for 5 minutes.
REPLACING THE POWER SUPPLY CABLE
Check that the power supply cable is in good condition, if not
have it replaced by an authorized service center.
REPLACEMENT OF BLADES (g.6)
For perfect operation and optimal tool performance, only use
originalFelisattiblades.Inordertottheblade,insert the
shank of the saw into the slot located on the lower part of
the gauge block on the saw support shaft, push the blade up
into position, locking in place with the special spanner, the
hexagonal headed screw should be positioned on the side
of the block. The hexagonal key is provided with the machine
andisinsertedinaholeonthesuctionsleeve,ttedonthe
support plate.
WARRANTY
See general warranty conditions printed on the attached
sheet.
NOISE AND VIBRATION
This tool has been designed and made to reduce noise to a
minimum. However, in spite of this, in certain circumstances
the maximum noise level in the place of work could exceed 85
dBA.Inthiscase,theoperatorshouldwearearprotection.
The machine’s noise and vibration levels, measured in
compliance with EN 60745, usually reach:
Acousticpressure=90dB(A)
Sound-powerlevel=101dB(A)
Use ear protection!
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Felisatti JSF120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Felisatti JSF120 in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info