ADDING START-UP CHEMICALS
WATER CHEMISTRY
GUIDELINES
The following step-by-step instructions are a
recommended guideline for balancing water
chemistry. If unsure about any step in the
process, please contact your local Dealer.
Initially, it is advisable to identify what minerals
(e.g. iron) are present in the local source water.
This will provide a better understanding of how
to treat the water. Please follow the four steps
below and be sure to achieve the correct levels
in each area before moving onto the next step.
ADD all chemicals into filter compartment while
running jets for 10 minutes.
STEP #1: ESTABLISH PROPER PH
LEVEL:
The recommended range for pH is between
7.2 and 7.8. If the reading is too high, lower
the pH by using a pH Down/Decreaser
(sodium bisulfate). If the pH level needs to
be increased, do so with a pH Up/Increaser
(sodium hydrogen carbonate). Any pH Up
or Down should be added one teaspoon
at a time, waiting one-half hour between
application and re-measuring.
STEP #2: MEASURE TOTAL
ALKALINITY:
The ideal range is between 40-120 parts
per million (PPM). If the total alkalinity is
too high, it should be reduced by using
an Alkalinity Down/Decreaser (sodium
bisulfate). If the total alkalinity is too low, it
can be increased by adding an Alkalinity UP/
Increaser (sodium bicarbonate or sodium
hydrogen carbonate). These products should
be added in small amounts – 5 ml at a time.
After adding 5 ml, wait one half hour before
re-measuring. Once the safe range of total
alkalinity is established, proceed to the next
step.
STEP #3: DETERMINE CALCIUM
HARDNESS:
It is important to bring the calcium reading to
between 50-150 PPM. If the reading requires
adjustment, it should now be corrected. If
the water is too soft (a low reading) calcium
hardness should be added to the water to
increase the PPM reading. If the water is too
hard (a high reading), it can be corrected by
either: (A) a mixture of hard and soft water
added to attain a reading in the safe range,
or (B) addition of stain and scale control. If
calcium hardness is a problem with the local
source water (either too hard or too soft) a
test kit, which measures calcium hardness, is
essential.
STEP #4: SANITIZING:
After steps 1-3 are complete, the spa must
be sanitized using Chlorine (sodium
dichlor). Add 2 teaspoons of Chlorine, and
increase as necessary to reach a level of
3-5 ppm. Check and maintain this level
weekly, and before and after using the spa.
IMPORTANT NOTE: A granulated sodium
dichlor is highly recommended for sanitizing
spa water, granular bromine may also be
used. Never use compressed sanitizers
even with a floater. As with any other
chemicals, the sanitizer should be introduced
to the spa with the jets running a minimum of
10 minutes.
WEEKLY SHOCK:
Using a potassium monopersulfate (MPS)
shock, add approximately 60 ml over the
filter while the jets are running. Shocking is
achieved by adding the MPS to turbulent
water. Leave the cover up and jets on high
for 10 minutes. Then shut jets off and return
the cover to the closed position to maintain
heat.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fantasy Splendor 2019 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fantasy Splendor 2019 in the language / languages: English as an attachment in your email.

The manual is 0.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info