605063
22
Zoom out
Zoom in
Previous page
1/24
Next page
CV Explanation Presetting. Value range
7 Software-Version 2-
8 Manufacturercode 85 -
47 Adresse HighByte 0 0-255
48 Adresse LowByte Adresse = CV47*256 + CV48 1 1-255
49 Configuration: 0 0-255
Bit 7 0=DCC 1=Mot
50 Speed of merry-go-round 60 0-255
51 Speed to go to limit switch 15 0-255
54 Speed for drive to zero 40 0-255
55 Time lag on starting in 1 ms steps 250 0-255
56 Time lag on braking in 1 ms steps 105 0-255
57 Running time of merry-go-round 102 0-255
98 Pause in 0.5 s steps 0 0-255
The data format for digital operation and digital operation mode is saved in the CV49.
To CV49:
DCC: Operation modes: with automatic CV49=0
without automatic CV49=1
Motorola: Operation modes: with automatic CV49=128
without automatic CV49=129
Note to CV49:
Do not use any other values! If the CV49 was programmed to 128 or 129,
the controls now only react to the Motorola data format and can only be put back
in DCC mode by means of key programming.
General note:
All CVs are only programmable with a DCC digital centre at the programming track output.
Note re. CV8:
If any random value is programmed in the CV8, all CVs will be reset back to the factory setting.
Operation:
Digital operation:
-------------------------------
Digital mode 1: (CV49-Bit0=0)
The start can be performed via the coil item address after that address has been given the status »green«.
All operating sequences will then be those of a start triggered using the start button.
Sound outputs:
Sound output 1 is activated for 0.5 s as soon as the merry-go-round is started.
Sound output 2 is activated at the end of the running time.
Key programming:
---------------------------------
The programming key cannot be used unless the attraction is at rest
(swing in its lowest position, reed sensor closed)!
1) Press the key -> the LED flashes 3 x
2) Now actuate some points on a Motorola control unit: the LED flashes 3 x and the address
has been adopted. The control unit displays the Motorola data format.
If a DCC capable control unit is used:
3) Press the key again -> the LED flashes 3 x
4) Now actuate some points on a DCC capable control unit: the LED flashes 3 x and the address has been
adopted. The control unit displays the DCC data format.
If no entry has to be made:
5) Press the key again -> the LED flashes 3 x. The control unit is in the working mode again.
Important:
-------------------
If key programming was used to set the control unit to Motorola data format, it cannot be read and
programmed via a DCC capable programming track.
If the control unit has to be set back again from Motorola data format to DCC data format,
it must first be set to the DCC mode through key programming.
Protection of motor power stage and stop outputs:
-------------------------------------------------------------------------------------------
The LED flashes rapidly -> Short-circuit at motor output.
The power stage switches off and the processor performs a reset after a few seconds.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FALLER 140424 Fahrgeschaft Crazy Clown at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FALLER 140424 Fahrgeschaft Crazy Clown in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info