Installation
Dear Installer
Before you start your installation, please
complete the details BELOW.
If your customer has a problem relating to your
installation they will be able to contact you
easily.
Thank you
Installer’s Name
Installer’s Company
Installer’s Telephone number
You must be aware of the following
safety requirements & regulations
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using this
appliance.
In the UK the regulations and standards are as follows:-
In your own interest and that of safety, it is law that all
gas appliances be installed by competent persons.
CORGI registered installers undertake to work to safe
and satisfactory standards. Failure to install the appliance
correctly could invalidate any warranty or liability claims
and lead to prosecution. The cooker must be installed in
accordance with
All relevant British Standards / Codes of
Practice, in particular BS 5440 Part 2 2000,
For Natural Gas - BS 6172 : 1990 and BS
6891 : 1998
For LP Gas - BS 5482-1:1994 (when the
installation is in a permanent dwelling), BS
5482-2:1977, (when the installation is in a
caravan or other non permanent dwelling), or
BS 5482-3:1999, (when the installation is in a
boat).
The Gas Safety (Installation and Use)
regulations 1998.
The relevant Building / IEE regulations.
Provision of Ventilation
This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to
the relevant requirements regarding ventilation.
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent, while
some rooms require a permanent vent in addition to the
openable window. The cooker should not be installed in a
bedsitting room with volume less than 20m
3
. If it is
installed in a room of volume less than 5m
3
an air vent of
effective area 100cm
2
is required; if it is installed in a
room of volume between 5m
3
and 10m
3
, an air vent of
effective area 50cm
2
is required; while if the volume
exceeds 11m
3
, no air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner but
NOT in a room containing a bath or shower.
NOTE:
An appliance for use on LPG shall not be
installed in a room or internal space below
ground level. e.g. in a basement.
Conversion
All models are supplied set for use on group H natural
gas. A conversion kit for Propane gas is included with the
appliance. See the instructions that are supplied with the
conversion kit. After converting the appliance please
attach the Gas Conversion sticker over the appropriate
area of the data badge, this will identify the gas type the
appliance is now set for.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Falcon 900 Deluxe at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Falcon 900 Deluxe in the language / languages: English as an attachment in your email.

The manual is 0,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info