MATRIX INDUCTION
TECHNICAL TRAINING
- 35 -
CU3A5
-
MATRIX
-
001
-
OPERATION
7.13. - “Error codes in the “MATRIX” induction hob
Action and faults displayed Result
Mains voltage fault
Mains overvoltage, check the mains supply, filter board
and mains cable.
Mains voltage fault
Mains under-voltage, check the mains supply U
eff
< 170V,
filter board and mains cable.
Mains synchro fault
Mains synchro signal absent, check the mains cables, the
filter board, the display assembly and the cabling.
Fan fault
Fan blocked or disconnected, check the 8/12V supply
voltage and the cabling
Microprocessor safety
The microprocessor has gone into safe mode, check the
supply voltage, the filter board, the cabling, the fans and the
installation.
NTC1 in short circuit, check the NTC value (2.5Kat
20°C)
NTC1 cut, check the NTC’s value (2.5Kat 20°C)
NTC1 fault on the power board on the
rectifier side.
Circuit board overheating, check the value of NTC1
(2.5Kat 20°C), the fans and the installation.
Short circuit in NTC2, check the NTC value (2.5Kat
20°C).
NTC2 cut, check the NTC’s value (2.5Kat 20°C).
NTC2 fault on the power board on the
microprocessor side.
Circuit board overheating, check the value of NTC2
(2.5Kat 20°C), the fans and the installation.
Inductor NTC faults (one NTC for three inductors
NTCI1 for inductor position 1-2-3 / NTCI2 for inductor position 4-5-6
NTCI3 for inductor position 7-8-9 / NTCI4 for inductor position 10-11-12
Short circuit in NTC, check the value of the NTC
(110Kat 20°C). Check the location, connection and
cabling.
NTC cut, check the value of the NTC (110Kat 20°C).
Check the location, connection and cabling.
NTC overheating, check the value of the (110Kat
20°C). Check the location, connection, cabling, use and
installation.
Inductor NTC fault
NTCI1 or NTCI2 or NTCI3 or NTCI4
NTC fault, check the value of the NTC (110Kà 20°C).
Check the location, connection and cabling.
NTCI1
1000
NTCI1
0100
NTCI1
0010
NTCI
1
0001
NTCE1
0100
NTCE1
0010
NTCE2
0001
NTCE1
0100
NTCE1
0010
NTCE1
0001
STOP
1
FAN
1
SYNC
1
VOLT
10
VOLT
01
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fagor IF-9000-S-MATRIX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fagor IF-9000-S-MATRIX in the language / languages: English as an attachment in your email.

The manual is 5,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info