473583
13
Zoom out
Zoom in
Previous page
1/38
Next page
MATRIX INDUCTION
TECHNICAL TRAINING
INSTALLATION
- 13 -
CU3A5
-
MATRIX
-
001
-
5.3. - Electrical connection
The maximum admissible power of the cable must be respected, relating to the length of the
cable and the power of the hob. Indeed, the longer the cable, the lower the transported power.
Maximum admissible theoretical power (in W) of the cables in relation to the length of
the connection and to the power
Cross-section in mm² 0.5 0.75 1 1.5 2.5 4 6 10 16
Maximum amperage (A) 3 6 10 16 25 30 40 60 80
The power of the hobs has increased considerably. The induction hobs may be fitted with cables
containing wires of different cross-sections.
Total power of the hob
Cross-section of wires
Circuit
protection (fuse)
Power 3.1 KW
1.5 mm²
16 A
Power 3.6 KW
1.5 mm²
16 A
Power 4.6 KW
2.5 mm²
16 A
Power 5.9 KW
2 x 2.5 mm² or 4 mm²
16 A
Power 7.2 KW
2 x 2.5 mm² or 4 mm²
32 A
Power 10.8 KW
1.5 mm² and 4 mm² or 2.5 mm² and 4 mm²
2 x 32 A
The MATRIX hob is fitted with two power supply cables.
One supply cable of 5 wires of 2.5 mm² with line connection protected by a 32A safety device.
One supply cable of 3 wires of 2.5 mm² with line connection protected by a 16A safety device.
5-WIRE SUPPLY CABLE 3-WIRE SUPPLY CABLE
16
A
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fagor IF-9000-S-MATRIX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fagor IF-9000-S-MATRIX in the language / languages: English as an attachment in your email.

The manual is 5,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info