1/ INSTALLING YOUR APPLIANCE
9
EN
•
ELECTRICAL CONNECTION
Your hob (which is supplied with an H05V2V2-
F type wire) must be connected to the 220-
240 V
~
single phase grid via a standardised
CEI 60083 2-pole + ground electrical outlet
plug or an all-pole cut-off device, in
compliance with the current regulations.
The electrical plug socket must remain
accessible after installation.
TYPE OF CABLE SECTION TO BE USED
H05V2V2F -T90 cable
Ref. After-sales
service: 77x9060
Conductor section
in mm
2
Fuse
220-240 V
~
- 50 Hz
3 conductors
including
1 ground
1
10 A
Warning
The safety wire (green/yellow) is
connected to the appliance’s ground terminal
and must be connected to the installation’s
ground terminal . A 10 amperes fuse must
be used in the installation. If the power cable is
damaged, it must be replaced by a cable or a
special kit which is available from the
manufacturer or their After-Sales Service
Department.
Tip
Using a gas cooking appliance generates
heat and humidity in its local vicinity. Make sure
that your kitchen is well-ventilated: ensure
natural ventilation openings in your home are
unobstructed or install a mechanical ventilation
device (mechanical ventilation hood). Intensive,
prolonged use of the appliance may require
additional ventilation; you can, for example,
open a window or provide more effective
ventilation by increasing the setting on a
mechanical ventilation system, where installed.
(a minimum air flow of 2 m
3
/hr per kW of gas
power is required).
For example : 30 cm - 2 gas burners
Total power : 1.5 + 3.1 = 4.6 kW
4.6 kW x 2 = 9.2 m
3
/h
minimum flow.