AHold the key pressed to turn the hood on/off at the first speed. The display shows 1.
BPress or move your finger from left to right to increase the speed from 1 to 2, 3,
Intensive.
The intensive speed is timed for 6 minutes. At the end of this time the system
automatically returns to the previously set speed.
Repeat the operation in reverse to decrease the speed (from right to left).
The display shows the selec-
ted speed.
If the Intensive speed is se-
lected the display shows an
animation.
Keypad Lock function
Long press of the leftmost lines, when all loads are off (Motor+Light):
activates/deactivates the keypad lock for hood cleaning.
All LEDs flashing
Induction/Gas Cooktop Selection
Long press of the rightmost lines, when all loads are off (Motor+Light):
select the type of cooktop in use, either Induction or Gas.
The Induction Cooktop is set by default.
1 Flashing LED A: confirms
the Induction Cooktop selec-
tion.
2 Flashing LED A: confirms
the Gas Cooktop selection.
CTurns the lights on/off at maximum intensity.
If there is an induction cooktop coupled with the hood and the hood is off, as
soon as the induction cooktop is turned on, the hood lights automatically turn on
at the maximum intensity.
Fixed
K-Link coupling
Before starting the procedure follow the specific instructions of the manuals of the
devices to be coupled.
Long press when all loads are off (Motor+Light):
starts the pairing procedure between the hood and compatible K-Link devices (in-
duction cooktop or remote control). Up to 3 induction cooktops can be paired and
only one remote control. See the manual of the devices for details of the opera-
tions that need to be performed on these.
The coupling procedure takes 2 minutes. If no devices are recognised within this
time check that you have previously activated the procedure for the devices to be
coupled. The maximum number of linkable devices may have been reached.
The display shows an anima-
tion:
coupling in progress.
Upon successful completion
of the procedure all the LEDs
will light up for 2 seconds.
DShort press: turns the lighting system on/off at medium intensity. Fixed
Long press when all loads are off (Motor+Light):
performs a saturated Filters alarm reset. The display shows F 3 times,
indicating that the filter reset
has been completed.
Signals the saturated Metal Grease Filters alarm and the need to wash them.
The alarm is activated after 100 hours of actual hood operation. With the motor off: the display
shows F + 1 multiple times al-
ternately.
Signals the saturated Activated Carbon Odour Filter alarm. The alarm is activ-
ated after 200 hours of actual hood operation. With the motor off: the display
shows F + 2 multiple times al-
ternately.
EShort press: activates/deactivates the Delay, the automatic delayed shutdown of
the Motor and Lighting system after 30 minutes. This mode cannot be activated if
Intensive or 24h is active.
Deactivate the function by pressing the same key or press the A key for about 1
second to shut down the motor.
LED A remains lit (fixed) and
LED E lights up. The display
shows an animation.
24h Function
Long press:
Activates/Deactivates the motor in the 24h Air Exchange mode, a speed that al-
lows suction of 10 minutes every hour, for a 24-hour cycle.
Cannot be activated if the Intensive or Delay modes are active.
LED A remains lit (fixed) and
LED E flashes. The display
shows an animation.
K-Link uncoupling
Long press when all loads are off (Motor+Light):
starts the procedure for the cancellation of all compatible K-Link devices previ-
ously paired with the K-Link Coupling function.
Upon successful completion
of the procedure all the LEDs
flash 5 times.
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Faber V-Air Flat KL A80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Faber V-Air Flat KL A80 in the language / languages: English, German, Dutch, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 2,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Faber V-Air Flat KL A80

Faber V-Air Flat KL A80 Installation Guide - English, German, Dutch, French, Italian, Polish, Turkish, Spanish - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info