Operating the Fire
This section describes how to activate your re using either the manual controls or remote control.
MANUAL CONTROLS
The manual controls are located beneath the hinged ap. Open the doors to access the controls. (See Fig.10 for
Manual Control lay out)
Switch ‘A’:- Controls the electricity supply to the Fire.
Note: This switch must be in the ‘ON’ ( I ) position for the Fire to operate either with or without heat.
Switch ‘B’:- Press
once to turn on the ame effect. This will be indicated by an audible beep. Although the main
lights operate immediately it will take a further 30 seconds before the ame effect starts.
Press again to give ame effect and half heat. This will be indicated by two beeps.
Press again to give ame effect and full heat. This will be indicated by three beeps.
Press again to return to ame effect only. This will be indicated by one beep.
Press to put re in to standby mode. This will be indicated by one beep.
Control Knob ‘C’:- Controls the Thermostat setting.
Turning the control knob to the left will decrease the temperature setting, turning the control knob
to the right will increase the temperature setting.
Control Knob ‘D’:- Controls the intensity of the ame effect.
Turning the control knob to the left increases the ame effect, turning the control knob to the right will
decrease the ame effect.
SETTING THE THERMOSTAT
Ensure the re is plugged in and switch it on to the full heat setting. Turn the Control Knob ‘C’ fully to the right (max
temperature setting) to warm the room rapidly. When the room temperature has reached the desired level, turn
the thermostat knob back slowly until you hear the thermostat just click off. The heater will then maintain the room
temperature at the chosen level.
Note: Should your heater fail to come on when the thermostat is at a low setting, this may be due to the room
temperature being higher then the thermostat setting
THERMAL SAFETY CUT-OUT
A thermal safety cut-out is incorporated in the fan heater to prevent damage due to overheating. This can happen
if the heat outlet was restricted in any way or if the chimney ue has not been blocked off effectively.. If the cut-out
operates, unplug the heater from the socket outlet and allow approximately 10 minutes before reconnecting. Before
switching the heater back on remove any obstruction that may be restricting the heat outlet, then continue normal
operation.
Caution: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be
supplied through an external switching device, such as a timer, or connected to a switch that is regularly switched
on and off by the utility. Depending on room temperature and humidity upon initial start up there may be some
condensation on the inside of the stove. This can be overcome by turning the ame control knob down and leaving the
door of the stove slightly ajar, until the glass warms up.
GETTING THE DESIRED FLAME EFFECT
1. The ame control knob ‘D’ (Fig.10) may be turned up or down to give a more realistic effect.
2. Generally the ames appear more realistic when the ame control is turned down.
3. Give the ame generator time to react to changes you may make.
4. The re will use less water if the ame effect is set to a lower level.
5. Do not tilt or move the re while there is water in the tank or sump.
6. Make sure that the re is on a level oor.
REMOTE CONTROL OPERATION
On the control panel, Switch A (see Fig.10) must be in the ‘ON’ ( I ) position in order for the remote control to operate.
There are 3 buttons on the remote control. (See Fig.12) To operate correctly the remote must be pointed towards the
front of the grate. (See Fig 17). The remote control functions are as follows:
Press once to turn on Flame effect only.
This will be indicated by one beep.
Press once to turn on Half Heat and Flame Effect.
This will be indicated by two beeps.
27
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Faber Stockbridge 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Faber Stockbridge 2.0 in the language / languages: English, German, Dutch, French, Norwegian as an attachment in your email.

The manual is 1,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info