Installation Instructions
13
The combined supply and discharge can be done both via wall or
through the roof or through an existing chimney. Verify if the
position of the terminal meets the local regulations regarding
ventilation openings.
The flue outlet can end on an external wall or a roof. Check
whether the outlet desired by you complies with local requirements
concerning good function and ventilation systems.
> Please note:
For a proper functioning the terminal should be at least 0,5m. away
from:
Corners of the building
Roof overhangs and balconies
Eaves (with the exception of the roof ridge, see Chapter 15)
3.4.1 C11, wall terminal
For a facade or wall outlet use a wall terminal (see fig. 1.9 C11).
Depending on the calculation this can be a diameter of
130/200mm or 100/150mm.
3.4.2 C31, roof terminal
For a flat or pits roof outlet use a long roof outlet with a diameter of
100/150mm (see fig. 1.9 C31).
3.4.3 C91, existing chimney
For an existing chimney use the short chimney outlet with a
diameter of 100/150mm (see fig. 1.9 C91).
In this case the existing chimney acts as air inlet an inserted flexible
stainless steel pipe discharges the flue gas. The top and the bottom
should be airtight.
Depending on the calculated outlet diameter, use a flexible
stainless steel tube of Ø100mm or Ø130mm with CE marking
for 600°C.
> Please note:
The minimum chimney diameter for a 130mm flexible stainless
steel pipe must 200x200mm. and for a 100mm flexible stainless
steel pipe 150x150mm.
The gas connection must comply with the applicable local
standards.
We advise using a Ø 15mm gas connection directly from the gas
meter to the appliance, with a shut-off valve in the proximity of the
appliance, which must always be freely accessible.
Position the gas connection so that it is easily accessible at all
times for service, and that the burner unit can be disassembled.
The power supply must comply with the applicable local standards.
A wall socket 230VAC/50Hz must be installed near the fire.
For power supply make use of the included plug adapter.
See fig 2.8 or 2.9 for the wiring diagram of this connection and the
LED Symbio module.
A = plug adapter
B = control unit
C = receiver
D = LED Symbio module
E = control block
F = magnet valve
4.2.1 Smart-Home installation
You can connect the control unit to the receiver with an external
source, such as a Domotica home automation system, using the
5-wire pin connector.
(Part G60-ZCE/1000, art.no.: 06022950). The total length of the
cable may not exceed 8m. Signal relay (gold-plated contacts) or
opto-couples are recommended!
4.2.2 Faber ITC (Intelligent Technical Controller)
The ITC gives you more options, such as ECO control, control,
error messages, maintenance advice and such.
For further information see the ”ITC” user manual.
You can also connect to an existing fireplace chimney. The existing
chimney functions then as air supply and a flexible stainless steel
tube drawn through the chimney carries the flue gases. The flexible
stainless steel tube of Ø100mm must have a CE mark have up to
600°C.
The chimney must have the following conditions:
The channel of the chimney must be at least 150x150mm.
There should be no more than one device on a chimney.
The chimney must be in good condition:
- no leakage
- well cleaned
For more information about connections to existing chimneys, ask
the installation manual “chimney connection set”.
Remove the fire from its packaging. Ensure that the gas
supply pipes under the appliance are not damaged.
Remove frame and glass and take the packaged parts from
the fire.
Store frame and glass in a safe place.
Prepare the gas connection on the regulator.
Take the installation requirements into account (see Chapter 3).
Place the appliance in the right position and set the height with the
(optional) leg levelers.
Height adjustment and levelling of the appliance (see point C, fig.
1.1).
Rough height adjustment:
With the extendable (optional) leg.
Fine adjustment:
With the adjustable feet.
3.4 Terminals
3.5 Existing chimney
4.3 Preparing the fire
4.1 Gas connection
4.2 Electrical connection
4.4 Positioning the fire
4 Preparation and installation
instructions
Downloaded from www.Manualslib.com manuals search engine
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Faber MatriX 800-serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Faber MatriX 800-serie in the language / languages: English as an attachment in your email.

The manual is 5,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info