560706
34
Zoom out
Zoom in
Previous page
1/57
Next page
33
LED AAN UIT
MAIN 220V~ netvoeding aanwezig 220V~ netvoeding afwezig
V ACC Vacc aanwezig Vacc afwezig
V MOT motorvoeding OK motorvoeding onderbroken
+ 24V + 24V aanwezig + 24V afwezig
OUT 3 contact OUT 3 gesloten contact OUT 3 open
OUT 2 contact OUT 2 gesloten contact OUT 2 open
OU 1 contact OUT 1 gesloten contact OUT 1 open
KEY ingang KEY gesloten ingang Key open
E-DET ingang E-DET gesloten ingang E-DET open
I-DET ingang I-DET gesloten ingang I-DET open
PSW 1 ingang PSW 1 gesloten ingang PSW 1 open
PSW 2 ingang PSW 2 gesloten ingang PSW 2 open
EM.1 ingang EMERG.1 gesloten ingang EMERG.1 open
EM.2 ingang EMERG.2 gesloten ingang EMERG.2 open
OPENED ingang OPENED gesloten ingang OPENED open
NIGHT ingang NIGHT gesloten ingang NIGHT open
MONODIR ingang MONODIR gesloten ingang MONODIR open
ERROR zie tabel
STATUS LED ERROR BETEKENIS
UIT normale bedrijfsconditie
AAN Alarmen nr. 18,20,22,24: er moet een SET-UP worden uitgevoerd
LANGZ. KNIPP. signalering alarm actief
SNEL KNIPP.
set-up/reset bezig of
tijdens de terugstelling met “bouwpakket elastiek” geactiveerd
ELEKTRONISCHE KAART SDM
DRUKKNOP BETEKENIS
RESET voert reset uit
SW5 impuls op ingang “interne sensor” (I-DET)
SETUP voert automatisch setup uit
SP-DOWN verlaagt de sluitingssnelheid
SP-UP verhoogt de sluitingssnelheid
CONNECTOR BETEKENIS
J1 secundaire 40V transformator
J2 secundaire 24V transformator
J3 connector snelkoppeling motor
J4 connector flat-cable encoder
J5 klemmenbord
J6 klemmenbord
J7 noodstop NOT AUS (contact NC)
J8 seriële poort RS232 verbinding PC
J11-J12-J13 connectors voor aanvullende kaarten
MAIN
V ACC
V MOT
+ 24V
OUT 3
OUT 2
OUT 1
KEY
E-DET
I-DET
PSW 1
PSW 2
EM.1
EM.2
OPENED
NIGHT
MONODIR
ERROR
DP
1 2
ON
J8
SW5
RESET
J5
J6
J13
J12
J11
F1
F2
J1
J3
J7
J2
J4
SP-DOWN
SETUP
SP-UP
1 2 3 4 5 6 7 8 9 10 11 12 13
1 2 3 4 5 6 7 8 9 10 11 12 13 14
J9
DP ON OFF
Dip n°1 draairichting motor (zie tabel)
Dip n°2 poort RS232 ingesteld poort RS232 ingesteld
voor SW update voor verbinding PC
ZEKERING BETEKENIS
F1 zekering 5x20 T 6.3A/250V (motorbescherming)
F2 zekering 5x20 T 1A/250V (bescherming 24V)
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC 930 N SF-SFA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC 930 N SF-SFA in the language / languages: Dutch as an attachment in your email.

The manual is 3,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info