TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM
Displays
Display Reason
off
Generator
o
sTaRT
The start-up phase is in progress
pelleT feeDinG
Continuous pellet feeding is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The
generator
is working at minimum
BloW
The automatic blow is active
final cleaninG
The nal cleaning is in progress
sTanD-By
Generator o waiting for re-ignition due to an external thermostat
coolinG WaiTinG
A new ignition is attempted when the generator has just been switched o. When the generator switches o, one must wait for
the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when these operations
have
been performed
.
H-off
Generator o due to water temperature over set
T - off
Generator o waiting for re-ignition due to all requests met
Black ouT WaiTinG
The generator
is cooling after a power cut.
Once cooling is completed, it will re-start automatically
anTi-fReeze
The anti-freeze function is in progress as the H2O temperature is below the factory set threshold
the pump is active until the water reaches the pre-set factory parameter +2°C
anTi-Block
The pump anti-block function is in progress (only if the generator has been in an OFF state for at least 96 hours); the pump is
activated for the time pre-set by the manufacturer, in order to prevent it from blocking
alaRMs
Display eXplanaTion soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor
The alarm can only be reset if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing key 1/
for 3 seconds.
fuMes MoToR
faulT
Fumes motor fault Contact after-sales centre
fuMes pRoBe
Flue gas probe fault. Contact after-sales centre
cHaMBeR pRoBe
Chamber probe fault. Contact after-sales centre
HoT fuMes
High fumes temperature
Check pellet feed (see “EASY SETUP”), if the problem cannot be solved,
contact an authorised technician.
35
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Virna Idro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Virna Idro in the language / languages: English as an attachment in your email.

The manual is 3,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Virna Idro

Extraflame Virna Idro User Manual - German - 40 pages

Extraflame Virna Idro User Manual - Dutch - 40 pages

Extraflame Virna Idro User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info