OFF
CONTROL BOARD
ON/OFF BUTTON VIEWING OF VARIOUS
TEXT MESSAGES
TO ACCESS
THE MENU
SETTINGS
TEMPERATURE
ADJUSTMENT
WORKING
TEMPERATURE
DISPLAY ICONS KEY
Indicates radio signal reception
Led o: radio communication not available.
Led on: radio communication available.
Flashing = serial port excluded
Indicates modulation of the stove
Led on: the stove is working at the set power
Flashing: The power at which the stove is working diers from the
set power, the stove is modulating (for various reasons)
Indicates the presence of an alarm.
O: indicates there are no alarms
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor.
Indicates the weekly programming status
O: deactivated
On: activated
Indicates the water temperature status
O= the T° read by the probe is higher than the set temperature
On= the T° read by the probe is lower than the set temperature
Indicates contact of the external additional thermostat
Contact closed on = the contact of the external additional
thermostat is closed.
Contact open on: the contact of the external additional thermostat
is open.
Flashing with contact closed: the contact of the external additional
thermostat is closed and the
STANDBY
function is enabled
Flashing with contact open: the contact of the external additional
thermostat is open and the
STANDBY
function is enabled
Indicates the status of the ue exhaust motor.
O = motor deactivated
On = motor activated
Flashing = fault
Indicates the summer/winter function
O: The winter function is activated
On: the summer function is activated
Not in use.
Indicates a request for DHW.
O: DHW supplied, pump o
Flashing: a request for DHW exists, but the operating conditions
have not been met. Pump o
On: the request for DHW is in progress and the operating conditions
have been met. Pump on
Indicates the status of the pellet loading motor.
O = motor deactivated
On = motor activated
Indicates a request for heating
O: DHW supplied, pump o
Flashing: a request for heating exists, but the operating conditions
have not been met. Pump o
On: the request for heating is in progress and the operating
conditions have been met. Pump on
It indicates pump operation
O = pump deactivated
On = pump activated
Flashing = the safety device is active (H2O temperature > 85°C)
Indicates a buer tank request, if active
O: buer tank request met, pump o
Flashing: a buer tank request exists, but the operating conditions
have not been met. Pump o
On: the buer tank request is in progress and the operating
conditions have been met. Pump on
17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Virna Idro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Virna Idro in the language / languages: English as an attachment in your email.

The manual is 3,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Virna Idro

Extraflame Virna Idro User Manual - German - 40 pages

Extraflame Virna Idro User Manual - Dutch - 40 pages

Extraflame Virna Idro User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info