SETTINGS
• DATETIME
• LANGUAGE
• DEGREES
See chapter: firSt ignition SettingS
DISPLAY
This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set
to maximum brightness and turns o after a 60 second delay.
The backlighting can be turned on again by pressing any key or if the stove is in the alarm condition.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until DISPLAY appears and conrm by pressing key 6.
Use keys 4-5 to set the desired intensity.
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
STAND BY
The STAND BY function, if enabled, is used when stove switch-o is to be controlled by means of an additional thermostat
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until STAND BY appears and conrm by pressing key 6.
Use keys 4-5 to enable (ON) / disable (OFF).
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
J
FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOWTA.
> SEE THE ADDITIONAL THERMOSTAT SETTINGS CHAPTER
STAND BY FUNCTION SET TO ON
If the STAND BY function is enabled (ON) and the room temperature exceeds the SET THERMOSTAT + DELTAT OFF value, then the stove
switches o after a preset factory delay, and STAND BY will be displayed on the screen.
When the room temperature is lower than the SET THERMOSTAT - DELTAT ON and after a possible cooling time, the stove switches back on.
STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND BY function is not enabled (OFF), if the stove exceeds the set room temperature, it will switch to the minimum power level,
modulating and displaying MODULATION on the screen. When the room temperature is lower than the SET THERMOSTAT the stove will
restart at the set power and WORK will be displayed on the screen.
OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL
STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND BY function is not activated (OFF), if the stove exceeds the room temperature set on the additional thermostat (open
contact), it switches to the minimum power level and displays MODULATION on the screen. When the room temperature is lower than the
set value on the additional thermostat (closed contact), the stove will resume operation at the set power, and WORK will be displayed on the
screen.
STAND BY FUNCTION SET TO ON
If the STAND BY function is activated (ON), when the room temperature set on the additional thermostat is reached (open contact), the stove
will switch o after a pre-set default delay period, and STAND BY will be displayed on the screen.
When the room temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling time,
the stove ignites again.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame SOUVENIR EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame SOUVENIR EVO in the language / languages: English as an attachment in your email.

The manual is 7.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame SOUVENIR EVO

Extraflame SOUVENIR EVO User Manual - German - 36 pages

Extraflame SOUVENIR EVO User Manual - Dutch - 36 pages

Extraflame SOUVENIR EVO User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info