36 ENGLISH
* on models with this function.
alaRMs
Display eXplanaTion soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset only if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing the key 1/ for 3 seconds.
fuMes MoToR
faulT Fumes motor fault Contact after-sales centre
fuMes pRoBe Fumes probe fault. Contact after-sales centre
HoT fuMes High fumes temperature Check pellet feed (see “Easy setup”), if the problem cannot be solved,
contact a qualied technician.
no
iGniTion
The pellet hopper is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy setup”).
Check the procedures described in the “Ignition chapter.
no flaMe
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy setup”).
DepR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
The air intake pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Check/clean air inlet.
* TRapDooR BlockeD
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
The ash drawer is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean. The automatic cleaning of the
burn pot is blocked.
If the problem persists, contact the service centre.
Check hermetic closure of the ash drawer.
* pRessuRe sensoR
DaMaGe
Dierential pressure sensor faulty, disconnected
or broken. Contact after-sales centre
* auGeR conTRol
alaRM Abnormal pellet feeding. Contact after-sales centre
* auGeR BlockeD Abnormal operation of pellet motor. Contact after-sales centre
* eMpTy HoppeR
The pellet hopper is empty.
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked.
Check for the presence of pellets in the hopper.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
MaX elecTRical cuR-
RenT
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean.
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre.
cHaMB pRoBe Chamber probe fault. Contact the after-sales centre.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame SINFONY at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame SINFONY in the language / languages: English as an attachment in your email.

The manual is 6.05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame SINFONY

Extraflame SINFONY User Manual - German - 40 pages

Extraflame SINFONY User Manual - Dutch - 40 pages

Extraflame SINFONY User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info