811697
24
Zoom out
Zoom in
Previous page
1/40
Next page
24 ENGLISH
FRONT AIR
This menu allows the upper ventilation motor speed to be set.
Range: (AUTO, COMFORT, OFF).
If comfort mode is selected, the upper air speed is reduced. If o mode is selected, the upper air is turned o.
To set: OK >FRONT AIR>SET
EASY SETUP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change while keeping the
quality of the pellet unchanged. By using the EASY SETUP function, it is possible to dose the pellets by increasing or decreasing the preset
values. In the stove program, the available values go from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value
which is 0
If you notice an excessive deposit on the burning pot, access the EASY SETUP program and lower the value to “- 1”; then wait until the next
day and if there is no improvement, decrease again, to a maximum of “- 3”.
If, on the other hand, it is necessary to increase the pellet dosage, switch the factory value from "0" to "+ 1, + 2, + 3" as required.
To set: OK > EASY SETUP
EXCESSIVE PELLET DEPOSIT IN BURN POT NORMAL OPERATION MINIMUM PELLET DEPOSIT IN BURN POT
-3 -2 -1 0 +1 +2 +3
THIRD DECREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
SECOND
DECREASE
RANGE IF
THE FIRST IS
INSUFFICIENT
FIRST DECREASE
RANGE (TEST FOR
1 DAY )
OPTIMAL FACTORY
VALUE FIRST INCREASE
RANGE
SECOND
INCREASE RANGE
IF THE FIRST IS
INSUFFICIENT
THIRD INCREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
N.B.: IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN POT, PLEASE CONTACT YOUR LOCAL
SERVICE CENTRE.
AIR ZONE CONTROL
This menu allows you to enable the AIR ZONE CONTROL mode
Range: (ON, OFF)
If ON is selected, the stove will optimise the adjustment so that the heat is sent to the ducting when the main room temperature set is
reached.
To set: OK > AIR ZONE CONTROL > SET
When the function is active, AIR ZONE CONTROL appears on the display
WARNINGS: If the appliance is installed with air ducting active, but ambient probe or thermostat for air ducting (i.e. the jumper is
kept on the ducting terminal), and the AIR ZONE CONTROL function is activated, it sends heat into the ducting regardless of the
temperature of the room receiving the ducting.
MODES
This menu allows you to set the machine operation logic. Range: (AUTOMATIC, SELF CONTROL)
If AUTOMATIC mode is selected, the stove power will be automatically adjusted to reach the set temperature without exceeding it.
This function improves the experience of using the generator in terms of consumption, thermal and acoustic comfort and the
reduction in the need for cleaning and maintenance.
If SELF CONTROL mode is selected, the stove will heat the room to the set temperature whilst maintaining the power set by the user.
To set: OK > MODE > SET
AIR DUCTING
This menu allows you to set the ducting motor speed. Range: (AUTO, COMFORT, OFF).
If COMFORT mode is selected, the ducting speed is reduced. If OFF is selected, the ducting is turned o.
Check that the ducting is not disabled; in this case follow the instructions given in the chapter HOT AIR DUCTING".
To set: OK >AIR DUCTING>SET
By connecting an external NTC probe or a radio probe* it is possible to view the room temperature and adjust the set TEMPERATURE.
To set: OK>AIR DUCTING>TEMPERATURE
*Optional accessories
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Sharon Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Sharon Plus in the language / languages: English as an attachment in your email.

The manual is 7.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Sharon Plus

Extraflame Sharon Plus User Manual - German - 40 pages

Extraflame Sharon Plus User Manual - Dutch - 40 pages

Extraflame Sharon Plus User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info