FIRST LOAD
This function allows the auger to be lled, thus facilitating rst stove ignition phases, or in the event the pellet hopper is empty. With the
stove cold and "OFF", make sure the pellets have been introduced inside the hopper and activate the FIRST LOAD function, conrming by
pressing OK.
To stop the continuous loading, simply press 1 for 3 seconds.
CONTROLS PROCEDURE
Press key 6.
press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until FIRST LOAD appears and conrm by pressing key 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to conrm and exit the menu.
RESET
Allows the user to reset all editable values to the default values.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing 3 until RESET appears and conrm by pressing 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to conrm and exit the menu.
DELTAT
This function allows the hysteresis thresholds to be set for stove ignition (DELTA-T ON) and switch-o (DELTA-T OFF), used as a room
temperature adjustment interval if not managed by an external thermostat.
The possible values for DELTAT go from: 0.5 - 5°C
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6
Press key 3 until DELTAT appears and conrm by pressing key 6.
Use keys 4-5 to set the desired value.
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
EASY CONTROL
The function allows for two values to be set:
OFF (disabled - factory default)
ON (enabled)
Activation (EASY CONTROL = ON) is recommended in the event that there is an excessive formation of combustion residues in the ue during
operation at reduced power (see FLUE EXHAUST chapter).
Caution! It is advisable to activate the EASY CONTROL function under the supervision of a qualied technician.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing 3 until EASY CONTROL appears and conrm by pressing 6.
Use keys 4-5 to enable "ON" / disable "OFF"
Press key 1 several times to conrm and exit the menu.
CLEANING
This function facilitates the normal cleaning of the combustion chamber by activating the ue gas fan.
With the stove cold and switched "OFF", activate the CLEANING function.
The message "DO THE CLEANING" appears.
Open the re door and, using the poker supplied, clean the combustion chamber.
When cleaning is complete, close the door and end the function.
CONTROLS PROCEDURE
Press key 6
Press key 3 until SETTINGS appears and conrm by pressing 6.
Keep pressing key 3 until CLEANING appears and conrm by pressing 6.
Clean the combustion chamber using the poker supplied.
Press key 1 to end and wait for the main screen to reappear.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Sabry 5.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Sabry 5.0 in the language / languages: English as an attachment in your email.

The manual is 5.96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Sabry 5.0

Extraflame Sabry 5.0 User Manual - German - 32 pages

Extraflame Sabry 5.0 User Manual - Dutch - 32 pages

Extraflame Sabry 5.0 User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info