811713
39
Zoom out
Zoom in
Previous page
1/44
Next page
39ENGLISH
Displays
upDate Reason
OFF Generator o
START The START phase is in progress
PELLET LOADING Continuous pellet feeding is in progress during the ignition state
IGNITION The phase dedicated to ignition is in progress
PREPARATION The ame stabilisation phase is in progress
WORK The generator has reached operating capacity and is working on user settings
MODULATION The generator is working at minimum capacity
FINAL CLEANING The cleaning cycle is in progress which is required to cool the machine before it is switched o
STAND-BY Generator o but in stand-by to reignite autonomously if required by operating requests
COOLING STAND BY The generator is requested to turn on during the shut-down phase. If activated, the generator will automatically
turn on again as soon as safety conditions permit it to do so
BLACK OUT
STAND BY The generator is cooling after a power cut. Once cooling is completed, it will re-start automatically
AUTO BLOW The auto blow is in progress to keep the burn pot
clean and maximise combustion eciency
EMPTY HOPPER
The pellet hopper is empty.
Check for the presence of pellets in the hopper.
Contact the after-sales centre.
CLOSE
HOPPER-STOVE DOOR
This indication means that you have 60 seconds to close the hatch/door and the pellet lid.
After 60 seconds have passed, the stove will enter DEPR ALARM during the ignition phase while during
normal operation, the stove will enter COOLING STAND BY and then, restart automatically when the conditions
are right (clod stove, etc.).
aiR Zone ContRol This message, visible in the WORK phase, indicates that the appliance is optimising the distribution of hot air
between the installation room and the ducted room.
alaRMs
Display eXplanation solution
FUMES MOTOR
FAULT Fumes motor fault Contact the after-sales centre
FUMES PROBE Fumes probe fault Contact the after-sales centre
HOT FUMES High fumes temperature Check the pellet ow (see “Pellet load adjustment”). If the problem
is not solve, contact a qualied technician
NO
IGNITION
The pellet hopper is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy setup”).
Check the procedures described in the “Ignition chapter.
Check bulb thermostats (see chapter on Resetting)
NO
IGNITION
BLACK OUT
No current during the ignition phase Take the stove to o conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
NO FLAME
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy setup”).
Check bulb thermostats (see chapter on Resetting)
DEPR ALARM
The door is not closed correctly
The combustion chamber is dirty
The fumes exhaust pipe is blocked/dirty
Check hermetic door closure.
Check cleanliness of the fumes pipe and the combustion chamber.
AUGER CONTROL
ALARM Abnormal pellet loading Contact after-sales centre
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame P70 AIR PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame P70 AIR PLUS in the language / languages: English as an attachment in your email.

The manual is 14.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame P70 AIR PLUS

Extraflame P70 AIR PLUS User Manual - German - 44 pages

Extraflame P70 AIR PLUS User Manual - Dutch - 44 pages

Extraflame P70 AIR PLUS User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info