32 ENGLISH
FIRST LOAD
This function allows you to activate the gearmotor for continuous pellet feeding.
Before starting the function, make sure the stove is cold and OFF”.
To set: OK > SETTINGS > FIRST LOAD
To stop continuous feeding, simply press and hold the key
OK
for 2 seconds.
QUICK ACCESS:
Before starting the function, make sure the stove is cold and OFF”.
Press keys
OK
+ at the same time for two seconds until the message "FIRST LOAD is displayed.
To stop continuous feeding, simply press and hold the key
OK
for 2 seconds.
DELTAT
This function allows the hysteresis thresholds to be set for stove ignition (DELTA-T ON) and switch-o (DELTA-T OFF), used as a room
temperature adjustment interval if not managed by an external thermostat.
The possible values of DELTA-T vary between 0.5 - 5 °C
To set: OK > SETTINGS> DELTAT
RESET
Allows the user to reset all editable values to the default values.
To set: OK > SETTINGS > RESET.
EASY CONTROL
The function allows for two values to be set:
OFF (disabled - factory default)
ON (enabled)
Activation (EASY CONTROL = ON) is recommended in the event that there is an excessive formation of combustion residues in the ue
during operation at reduced power (see FLUE EXHAUST chapter).
Caution! It is advisable to activate the EASY CONTROL function under the supervision of a qualied technician.
To set: OK > SETTINGS > EASY CONTROL
TA ADDITIONAL THERMOSTAT OPTIONAL
The appliance is able to control the room temperature through an additional thermostat (optional).
After ignition (by pressing key 1 or in chrono mode), the stove will work to reach the set value on the thermostat, displaying WORK (closed
contact) on the screen. The room sensor incorporated into the handheld device is automatically ignored.
INSTALLATION MUST BE PERFORMED BY QUALIFIED STAFF AND/OR THE MANUFACTURER'S SERVICE TECHNICIANS
TO INSTALL AND ACTIVATE:
A mechanical or digital thermostat is required.
Remove the plug from the socket.
Using the image to the side as a guide, connect the two thermostat wires (clean contact - no 230 V!) to
the respective terminals at the back of the machine, one red and the other black.
Connect the power to the stove again.
Press the key (
OK
), until the set temperature is set to LOW-TA.
The stove is now correctly congured.
It will work by checking the external additional thermostat based on the TA function.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame P70 AIR PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame P70 AIR PLUS in the language / languages: English as an attachment in your email.

The manual is 14.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame P70 AIR PLUS

Extraflame P70 AIR PLUS User Manual - German - 44 pages

Extraflame P70 AIR PLUS User Manual - Dutch - 44 pages

Extraflame P70 AIR PLUS User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info