wITH PROBE (NTC 10K)
Remove the jumper and connect the NTC probe in the room that needs to be temperature-controlled through air ducting.
2 control modes:
OPERATION IN AIR DUCTING wITH AMBIENT THERMOSTAT (OPTIONAL)
SET congured to AUTO
(The temperature setting is not visible)
Once the specic activation threshold has been reached and exceeded, at temperature
to be satised (CLOSED CONTACT) the air ducting motor will follow the stove settings.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch to minimum and then follow the stove settings again when
there is a new request.
SET congured to COMFORT
(The temperature setting is not visible)
Once the specic activation threshold has been reached and exceeded, at temperature
to be satised (CLOSED CONTACT) the air ducting motor will follow the stove settings
but at a lower speed than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch to minimum and then follow the stove settings again, but
at a lower speed when there is a new request.
OPERATION IN AIR DUCTING wITH NTC PROBE 10KΩ (OPTIONAL)
SET congured to AUTO
Set the desired temperature ( from 7 to 37 °C)
Once the specic activation threshold has been reached and exceeded, at temperature
to be satised the air ducting motor will follow the stove settings.
When the set TEMPERATURE is reached, the air ducting motor will switch to
minimum and then follow the stove settings again when there is a new request.
SET congured to COMFORT
Set the desired temperature ( from 7 to 37 °C)
Once the specic activation threshold has been reached and exceeded, at temperature
to be satised the air ducting motor will follow the stove settings but at a lower speed
than in SET AUTO for increased acoustic/ambient comfort.
When the set TEMPERATURE is reached, the air ducting motor will switch to
minimum and then follow the stove settings again, but at a lower speed when there
is a new request.
oPerAtion in Air ductinG with thermostAt or Probe (oPtionAl)
The stove is tted with an independent motor for ducting. The connection of an external thermostat or temperature probe (NTC 10K) in the
input, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove.
Suce it to connect the thermostat/temperature probe and set the desired temperature.
For information on air ducting settings see chapter:" Menu - r AIr DuCTInG"
wITH AMBIENT THERMOSTAT (OPTIONAL)
Remove the jumper and connect the ambient thermostat in the room that needs to be temperature-controlled through air ducting 1.
2 control modes:
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame P70 AIR PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame P70 AIR PLUS in the language / languages: English as an attachment in your email.

The manual is 14.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame P70 AIR PLUS

Extraflame P70 AIR PLUS User Manual - German - 44 pages

Extraflame P70 AIR PLUS User Manual - Dutch - 44 pages

Extraflame P70 AIR PLUS User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info