ENGLISH
* on applicable models
fuMes pRoBe
Fumes probe failure. Contact after-sales centre
HoT fuMes
High ue gas temperature
Check pellet feed (see “Pellet feed adjustment”). If the problem cannot be
solved, contact an authorised technician.
all clean cHecH up
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air channel
and the combustion chamber.
no
iGniTion
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped
Check for the presence of pellets in the feed-box.
Adjust pellet ow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
Check the bulb thermostats (see Rearms chapter)
no iGniTion
Black ouT
No current during the ignition phase.
Set the stove on OFF using key 1 and repeat the procedure described in the
"Ignition" chapter.
no pelleTs
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed pellets.
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see “Pellet feed adjustment”).
DepRession alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked/dirty.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
DeBiMeTeR
faulT
Flow sensor faulty.
Sensor disconnected
Contact after-sales centre
H20 oveRTeMp
Air in the system
Unsuitable circulation
Possible air in the system, vent the system.
Lack of adequate circulation.
Lack of or inadequate safety zone.
The water in the stove has exceeded 95°C.
Possible circulator anomaly.
If the problem persists, the reset operations must be carried out by an
authorised technician.
* TRapDooR faulTy
The automatic burn pot cleaning is blocked.
Burn pot dirty or clogged
The door is not closed correctly.
Check closure of the door.
Check that the burn pot is clear and clean.
The automatic burn pot cleaning is blocked.
If the problem persists contact the service centre
all-Min H2o pRes-
suRe
The system pressure read by the pressure switch
is too low.
Possible air in the system, vent the system.
Possible lack of water or leaks due to anomalies in some system component.
If the problem persists contact the service centre
H2o pRoBe
H2O probe failure Contact after-sales centre
all-Max H2o pRes-
suRe
The pressure of the water has exceeded the max
threshold
Possible air in the system, vent the system.
Check that the expansion vessels are not damaged or under-dimensioned
Check that the cold system is loaded at the correct pressure
If the problem persists contact the service centre
* pRessuRe sensoR
faulTy
Defective, disconnected or faulty dierential
pressure sensor.
Contact after-sales centre
* auGeR conTRol
Anomalous pellet loading. Contact after-sales centre
* auGeR Block
Anomalous functioning of the motor. Contact after-sales centre
* BoileR pRoBe
Boiler probe failure. Contact after-sales centre
* puffeR pRoBe
Boiler probe failure. Contact after-sales centre
* Tank eMpTy
The pellet feed-box is empty.
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
Check for the presence of pellets in the feed-box.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
28
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Megan Idro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Megan Idro in the language / languages: English as an attachment in your email.

The manual is 5,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Megan Idro

Extraflame Megan Idro User Manual - German - 32 pages

Extraflame Megan Idro User Manual - Dutch - 32 pages

Extraflame Megan Idro User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info