32 ENGLISH
Displays
Display Reason
off
Generator o
sTaRT
The start-up phase is in progress
pelleT loaDinG
Continuous pellet feeding is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The generator is working at minimum
final cleaninG
The nal cleaning is in progress
sTanD-by
Generator o waiting for re-ignition due to the external thermostat.
coolinG sTanD by
A new ignition is attempted when the generator has just been switched o. When the generator switches o, you must
wait for the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when
these operations have been performed.
black ouT sTanD
by
The generator is cooling after a power cut.
Once cooling is completed, it will re-start automatically
auTo bloW
The automatic blow is active
alaRMs
Display eXplanaTion soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm.
The alarm can only be reset if the fumes motor has stopped and 15
minutes have passed since the alarm was displayed, by pressing key 1
for 3 seconds.
e00
Fumes motor fault Contact after-sales centre
e01
Fumes probe fault. Contact after-sales centre
e02
High fumes temperature
Check pellet feed (see “Easy”), if the problem cannot be solved, contact
an authorised technician.
e03
NO IGNITION
The pellet hopper is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy”).
Check the procedures described in the “Ignition chapter.
e04
NO FLAME
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy”).
e05
DEPR ALARM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
e06
NO IGNITION BLACK OUT
No current during the ignition phase.
Turn the stove off using key 1 and repeat the procedure described in
the "Ignition" chapter.
Other reset operations should be performed by an authorised
technician.
e07
Triac
Abnormal pellet loading.
Contact after-sales centre
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Luisella at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Luisella in the language / languages: English as an attachment in your email.

The manual is 3,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Luisella

Extraflame Luisella User Manual - German - 36 pages

Extraflame Luisella User Manual - Dutch - 36 pages

Extraflame Luisella User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info