23ENGLISH
STBY STAND-BY)
The stand-by function is used if the stove needs to be turned o immediately instead of a power modulation.
CONTROLS PROCEDURE
Press and hold key 4.
Press key 3 until SET appears and access with key 4.
Press key 3 until STBY appears and access with key 4.
Enable/disable using keys 4 and 5 and conrm with key 2.
Press key 1 several times to exit the menu.
DATE
DAY
TIME
LNG
CF
SEE CHAPTER: COMMISSIONING SETTINGS.
J
FOR CORRECT OPERATION, SET THERMOSTAT SHOULD BE SET IN LOU.
> SEE THE INSTALLATION CHAPTER SUPPLEMENTARY THERMOSTAT
SET SETTINGS
STBY FUNCTION SET TO ON
When the Stand-by function is active (ON), if the room temperature exceeds the SET THERMOSTAT value + DELT, the stove will switch o
after a pre-set (default) delay period, displaying STBY.
When the room temperature is lower than the SET THERMOSTAT - DELT, the stove cools down, if necessary, and then switches o.
STBY FUNCTION SET TO OFF FACTORY DEFAULT SETTING
In the event the Stand-by function is not activated (OFF), if the stove exceeds the set room temperature, it will switch to the minimum power
level, modulating and displaying MODULATION. When the room temperature is lower than the SET THERMOSTAT the stove will restart at
the set power and WORK will be displayed on the screen.
OPERATION WITH SUPPLEMENTARY THERMOSTAT OPTIONAL
STBY FUNCTION SET TO OFF FACTORY DEFAULT SETTING
In the even the Stand-by function is not activated (OFF), if the stove reaches the room temperature set on the supplementary thermostat
(closed contact), it will switch to the minimum power level and display MODULATION. When the room temperature is lower than the set value
on the supplementary thermostat (open contact), the stove will restart at the set power, and WORK will be displayed on the screen.
STBY FUNCTION SET TO ON
If the STAND-BY function is activated (ON), when the room temperature set on the supplementary thermostat is reached (closed contact), the
stove will switch o after a pre-set (default) delay period, and STBY will be displayed on the screen.
When the room temperature is lower than the supplementary thermostat (open contact), the stove cools down, if necessary, and then re-
ignites.
DELT DELTAT
This function allows you to set the delta-t for igniting and switching o the stove, used as a room temperature adjustment interval if there
is no external thermostat. The exact temperature for ignition is SET THERMOSTAT - Delta-T. The temperature for switching o is SET
THERMOSTAT + Delta-T.
The possible values for Delta-T range from: 0.5 - 5°C
CONTROLS PROCEDURE
Press and hold key 4.
Press key 3 until SET appears and access with key 4.
Press key 3 until DELT appears and access with key 4.
Adjust with keys 4-5 and 2 to conrm.
Press key one several times to conrm and exit the menu.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame Luisella at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame Luisella in the language / languages: English as an attachment in your email.

The manual is 3,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame Luisella

Extraflame Luisella User Manual - German - 36 pages

Extraflame Luisella User Manual - Dutch - 36 pages

Extraflame Luisella User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info