HYDRAULIC SYSTEM
Certain concepts referring to the Italian UNI 10412-2 (2009) Standard are described in this chapter.
As previously described, when installing, all national, regional, provincial and town council Standards in force provided by the
country in which the appliance has been installed must be complied with.
During installation of the stove it is MANDATORY to adjust the system with a manometer in order to display the water pressure.
INSTALLATION AND SAFETY DEVICES
The installation, relative system connections, commissioning and inspection of correct functioning must be carried out perfectly,
in full compliance with Standards in force, national, regional and municipal, as well as these instructions.
For Italy, installation must be carried out by professionally authorised sta (Ministerial Decree dated 22.01.08 n°37).
Extraame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system.
SAFETY DEVICES FOR CLOSED VESSEL SYSTEM
According to the UNI 10412-2 (2009) Standard in force in Italy, the closed systems must have: safety valve, pump control
thermostat, acoustic alarm activation thermostat, temperature indicator, pressure indicator, acoustic alarm, regulation automatic
circuit breaker switch, automatic circuit breaker block switch (block thermostat), circulation system, expansion system, safety
dissipation system incorporated with the generator with thermal safety valve (self-activated), whenever the appliance does not
have a temperature self-adjustment system.
DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD
The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the ow connection.
Whenever the generators lack a device, those missing can be installed on the generator ow pipe, within a distance no greater
than 1m from the machine.
| ENGLISH
TABLE OF SAFETY DEVICES FOR CLOSED VESSEL SYSTEM
AND NOT PRESENT IN THE PRODUCT
Safety valve R
Pump control thermostat (it is managed by the water
probe and the board program) R
Acoustic alarm activation thermostat
Water temperature indicator (display) R
Pressure indicator
Acoustic alarm
Regulation automatic circuit breaker switch (managed
by board program) R
Minimum and maximum pressure pressure switch R
Water overheating automatic circuit breaker switch (block
thermostat) R
Circulation system (pump) R
Expansion system R
SAFETY DEVICES
CIRCUIT BOARD:
Intervenes directly by sending the product into alarm conditions until
complete cooling, in the case of: breakage of ue gas motor, pellet
feed motor breakage, black out (if more than 10 seconds), no ignition
FLOW SENSOR:
In the event of inadequate ow, it takes the machine to alarm conditions
F2.5 A 250V FUSE STOVES:
Protect the machine from violent current drops
85 CALIBRATED MECHANICAL BULB WITH MANUAL REARM:
Intervenes by blocking fuel feed whenever the pellet tank t° reaches
the limit of 85°C. Rearm must be performed by qualied sta and/
or the manufacturer's technical after-sales assistance.
100°C CALIBRATED MECHANICAL BULB WITH MANUAL REARM:
Intervenes by blocking the fuel feed whenever the t° of the water
inside the product is near to 100°. Rearm must be performed by
qualied sta and/or the manufacturer's technical after-sales
assistance.
MINIMUM AND MAXIMUM PRESSURE SWITCH:
Intervenes in the event of inadequate water pressure. Rearm must
be performed by qualied sta and/or the manufacturer's
technical after-sales assistance.
MECHANICAL AIR PRESSURE SWITCH:
Blocks the pellet in the event of insucient depression
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame LP20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame LP20 in the language / languages: English as an attachment in your email.

The manual is 4.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame LP20

Extraflame LP20 User Manual - German - 40 pages

Extraflame LP20 User Manual - Dutch - 40 pages

Extraflame LP20 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info