LP14 - 20 LCD USER MANUAL
ENGLISH/ INGLESE
index
3
We thank you for having chosen our company; our product is a great heating solution developed from the
most advanced technology with top quality machining and modern design, aimed at making you enjoy
the fantastic sensation that the heat of a ame gives, in complete safety.
Extraame S. p. A.
enGLiSH ....................................................................................................................................................................................................................................5
TecHnicaL feaTureS ..............................................................................................................................................................5
inTrOducTiOn .........................................................................................................................................................................6
WarninGS ..................................................................................................................................................................................8
SafeTy ........................................................................................................................................................................................8
HydrauLic SySTeM ..................................................................................................................................................................9
InstallatIon and safety devIces................................................................................................................................................................................. 9
safety devIces for closed vessel system ............................................................................................................................................................. 9
dIstances of safety devIces accordIng to the standard ........................................................................................................................ 9
Type Of SySTeM ...................................................................................................................................................................... 10
closed vessel system ........................................................................................................................................................................................................10
safety valves ........................................................................................................................................................................................................................... 10
closed expansIon vessel ................................................................................................................................................................................................. 11
commIssIonIng checks .....................................................................................................................................................................................................11
automatIc thermostatIc mIxer valve (mandatory) .....................................................................................................................................11
HydrauLic SySTeM baSic LayOuT .....................................................................................................................................12
inSTanT dOMeSTic HOT WaTer prOducTiOn kiT ...........................................................................................................13
stove posItIonIng ................................................................................................................................................................................................................13
rearM ....................................................................................................................................................................................... 13
THerMO-prOducTS feaTureS ............................................................................................................................................13
SafeTy deviceS ...................................................................................................................................................................... 14
reference STandardS ........................................................................................................................................................14
general .......................................................................................................................................................................................................................................15
inSTaLLaTiOn ..........................................................................................................................................................................16
fuMeS exHauST SySTeM.......................................................................................................................................................17
general requIrements .....................................................................................................................................................................................................17
smoke duct ...............................................................................................................................................................................................................................18
chImney .......................................................................................................................................................................................................................................20
chImney caps ...........................................................................................................................................................................................................................20
combustIon products outlet quota .................................................................................................................................................................... 21
fumes exhaust system product requIrements ..............................................................................................................................................21
technIcal InstallatIon documentatIon .............................................................................................................................................................22
peLLeTS and feedinG ...........................................................................................................................................................23
index
4
cOnTrOL bOard .....................................................................................................................................................................24
dIsplay Icons key ..................................................................................................................................................................................................................24
GeneraL Menu .......................................................................................................................................................................25
basIc InstructIons .............................................................................................................................................................................................................25
cOMMiSSiOninG SeTTinGS ...................................................................................................................................................26
adjustIng the tIme, day, month and year ............................................................................................................................................................26
adjustIng the language .................................................................................................................................................................................................26
OperaTiOn and LOGic ..........................................................................................................................................................27
addiTiOnaL THerMOSTaT .................................................................................................................................................... 28
addItIonal thermostat functIonIng wIth stby actIve.............................................................................................................................28
addItIonal thermostat InstallatIon ....................................................................................................................................................................28
aux ............................................................................................................................................................................................ 28
Menu STrucTure ...................................................................................................................................................................29
set power ................................................................................................................................................................................................................................. 30
set temperature ....................................................................................................................................................................................................................30
set adjustments ..................................................................................................................................................................................................................30
enable chrono.......................................................................................................................................................................................................................30
pellet regulatIon ................................................................................................................................................................................................................ 30
user menu ..................................................................................................................................................................................................................................31
chrono ........................................................................................................................................................................................................................................ 31
programmIng example .....................................................................................................................................................................................................32
adjustIng language ..........................................................................................................................................................................................................33
dIsplay .........................................................................................................................................................................................................................................33
reset ..............................................................................................................................................................................................................................................33
OTHer funcTiOnS ..................................................................................................................................................................33
aIr dIscharge ..........................................................................................................................................................................................................................33
fIrst load ...................................................................................................................................................................................................................................33
cLeaninG under uSer'S reSpOnSibiLiTy.........................................................................................................................34
rOuTine MainTenance .......................................................................................................................................................35
diSpLayS ..................................................................................................................................................................................37
aLarMS ....................................................................................................................................................................................38
| ITALIANO
5
TECHNICAL FEATURES
FEATURES LP 14 LP 20
Weight kg 220 260
Height mm 1327 1368
Width mm 533 525
Depth mm 663 941
Flue exhaust pipe diameter mm 120 120
Air intake pipe diameter mm 60 60
Max. global heat output kW 15.7 22.3
Max. useful thermal power (to the water) kW 14.7 20.9
Minimum global heat output kW 4.2 4.2
Min. useful heat output kW 3.9 3.9
Max. hourly fuel consumption kg/h 3.3 4.6
Min. hourly fuel consumption kg/h 0.9 0.9
Tank volume l ~ 61 ~ 100
Recommended ue draught mbar ~ 0.1 ~ 0.1
Nominal electric output W 470 470
Nominal voltage Vac 230 230
Nominal frequency Hz 50 50
Water inlet/outlet pipe diameter 1 1
Automatic exhaust pipe diameter 1/2 1/2
Pump head m 5 5
Max. working water pressure accepted bar 2.5 2.5
Min. working water pressure accepted bar 0.6 0.6
Flue gas temperature °C 53.3 - 75.8 53.3 - 84.6
Flue gas ow rate g/s 6.5 - 11.1 6.5 - 13.7
Boiler class 3 3
Combustion period h 43 - 13 70 - 15
Water thermostat eld of regulation °C 65 - 80 65 - 80
Water return minimum temperature °C 55 55
Dimensions of the feeding door mm 286 L x 225 D 370 L x 360 D
Yield % 93.4 93.7
LP14 FLOW OF WATER
(kg/h)
WATER SIDE
RESISTANCE
(mbar)
Corresponding temperature dierence ΔT = 10K 1264.2 72.7
ΔT = 20K 632.1 67.8
LP20 FLOW OF WATER
(kg/h)
WATER SIDE
RESISTANCE
(mbar)
Corresponding temperature dierence ΔT = 10K 1797.4 100
ΔT = 20K 898.7 88.6
| ENGLISH
6
INTRODUCTION
The boilers produced in our establishment are built with attention to the individual components so as to protect both the user
and the installer from any accidents. It is therefore recommended that after any intervention on the product, that authorised
sta pay particular attention to the electric connections, especially the stripped parts of the wires. These must not escape from
the terminal board in any situation, thus preventing possible contact with the live parts of the wire.
The instruction manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred
to other owners or user or is transferred to another place. If it is damaged or lost,request another copy from the area technician.
This boiler must be intended for the use it has been specically made for. The manufacturer is exempt from any liability,
contractual and extracontractual, for injury/damage caused to persons/animals and objects, due to installation, adjustment
and maintenance errors and improper use.
INSTALLATION
Installation of the boiler and auxiliary equipment in relation to the heating system must comply with all current Standards and
Regulations and to those envisioned by the law. Installation must be carried out by authorised sta, who must provide the buyer
with a declaration of conformity for the system and will assume full responsibility for nal installation and as a consequence the
correct functioning of the installed product.
It is necessary to bear in mind all laws and national, regional, provincial and town council Standards present in the country the
appliance has been installed.
Extraame S.p.A. cannot be held responsible for the failure to comply with such precautions. It is recommended to wash all
the pipes of the system well before installation to remove any residue that could compromise the correct operation of the
appliance. During installation, inform the user regarding:
a. If water leaks, he must close the water supply and promptly inform the after-sales technical service.
b. The system working pressure must be checked periodically. If the boiler is not used for a long period of time, it is recommended
to contact the after-sales technical service to carry out at least the following operations:
- Set the master switch to position 0.
- Close the water taps of both the heating system and the domestic hot water system.
- Empty the heating system and the domestic hot water system if there is risk of freezing.
COMMISSIONING
After removing the packaging, ensure that the content is intact and complete.
Otherwise, contact the dealer where the appliance was purchased from.
When commissioning the product, verify that all safety and control devices that the boiler consists of work well. All electrical
components that make up the boiler must be replaced with original spare parts exclusively by an authorised technical assistance
centre, thereby guaranteeing correct operation.
Before leaving the system, the sta in charge of commissioning must monitor boiler operation for at least one complete work
cycle. The boiler must be serviced at least once a year, programming it in advance with the technical assistance centre.
APPROVALS
The Extraame boilers have been designed and realised in compliance with the following Directives:
UNI EN 303-5 Boilers for central heating. Boilers for solid fuel, with manual and automatic feeding, with a nominal heat
output of up to 300 kW
Compliance with the Low Voltage Directive (73/23 EEC)
Compliance with the EMC Directive (Electromagnetic compatibility 89/336 EEC)
FOR SAFETY
It is forbidden for the boiler to be used by children or unassisted disabled persons.
Do not touch the boiler when you are barefoot or when parts of the body are wet or humid.
The safety and adjustment devices must not be modied without the authorisation or indications of the manufacturer.
Do not pull, disconnect, twist electric cables leaving the boiler, even if disconnected from the electric power supply mains.
Do not close or reduce the dimensions of the airing vents in the place of installation.
The airing vents are indispensable for correct combustion.
Do not leave the packaging elements within reach of children or unassisted disabled persons.
The hearth door must always be closed during normal functioning of the product.
Avoid direct contact with parts of the appliance that tend to heat up during functioning.
Check for the presence of any obstructions before switching the appliance on following a prolonged standstill period.
| ENGLISH
663 mm
530 mm
A
B
A
C
525 mm
941 mm
C
D
EE
A
B
D
A
LP14 LP20
7
The boiler has been designed to function in any climatic condition (also critical). In particularly adverse conditions (strong
wind, freezing) safety systems may intervene that switch the boiler o.
If this occurs, contact the technical after-sales service and always disable the safety system.
If the ue should catch re, be equipped with suitable systems for suocating the ames or request help from the re
service.
If the boiler should block, indicated by a signal on the display and that is not relative to lack of routine maintenance,
contact the technical after-sales centre.
THESE BOILERS MUST BE USED TO HEAT WATER TO A TEMPERATURE THAT DOES NOT EXCEED BOILING
POINT IN THE CONDITIONS OF INSTALLATION.
RECOMMENDED DISTANCES FOR THE BOILER COMPARTMENT
Below are a few images relative to the minimum distances required in the boiler room.
The company recommends the following measurements to be complied with:
REFERENCES NONINFLAMMABLE OBJECTS REFERENCES NONINFLAMMABLE OBJECTS
A500 mm D300 mm
B1,000 mm E> 80 cm2
C1,000mm - -
| ENGLISH
8
WARNINGS
The instruction manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred
to another owner or user or if transferred to another place. If it is damaged or lost,request another copy from the area technician.
This product must be intended for the use it has been specically made for. The manufacturer is exempt from any liability,
contractual and extracontractual, for injury/damage caused to persons/animals and objects, due to installation, adjustment
and maintenance errors and improper use. Installation must be performed by qualied sta, which assumes complete
responsibility for the denitive installation and consequent good functioning of the product installed. It is necessary to
bear in mind all laws and national, regional, provincial and town council Standards present in the country the appliance
has been installed.
Extraame S.p.A. cannot be held responsible for the failure to comply with such precautions.
After removing the packaging, ensure that the content is intact and complete. Otherwise, contact the dealer where the appliance
was purchased from.
All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after-
sales centre, thus guaranteeing correct functioning.
SAFETY
The stove must not be used by persons (including children) with reduced physical, sensorial and mental capacities or who
are unskilled, unless they are supervised and trained regarding use of the appliance by a person responsible for their safety.
Children must be monitored to ensure they do not play with the appliance.
Do not touch the stove when you are barefoot or when parts of the body are wet or humid.
The safety and adjustment devices must not be modied without the authorisation or indications of the manufacturer.
Do not pull, disconnect, twist electric cables leaving the stove, even if disconnected from the electric power supply mains.
It is recommended to position the power supply cable in a way that it does not come into contact with hot parts of the
appliance.
The power supply plug must be accessible after installation.
Do not close or reduce the dimensions of the airing vents in the place of installation. The airing vents are indispensable
for correct combustion.
Do not leave the packaging elements within reach of children or unassisted disabled persons.
The hearth door must always be closed during normal functioning of the product.
When the appliance is functioning and hot to the touch, especially all external surfaces, attention must be paid
Check for the presence of any obstructions before switching the appliance on following a prolonged standstill period.
The stove has been designed to function in any climatic condition (also critical). In particularly adverse conditions (strong
wind, freezing) safety systems may intervene that switch the stove o. If this occurs, contact the technical after-sales service
and always disable the safety system.
If the ue should catch re, be equipped with suitable systems for suocating the ames or request help from the re
service.
This appliance must not be used to burn waste
Do not use any inammable liquids for ignition
During the lling phase do not allow the bag of pellets to come into contact with the product
The majolicas are top quality artisan products and as such can have micro-dots, crackles and chromatic imperfections.
These features highlight their valuable nature. Due to their dierent dilation coecient, enamel and majolica produce
crackling, which demonstrate their eective authenticity. To clean the majolicas, it is recommended to use a soft, dry cloth. If
a detergent or liquid is used, the latter could penetrate the crackles, thereby making them show more.
ROUTINE MAINTENANCE
Based on the Decree 22 January 2008 n°37 art.2, routine maintenance means interventions aimed at reducing degradation from
normal use, as well as dealing with accidental events entailing the need of rst interventions, which however do not modify the
structure of the system upon which one is intervening or its intended use according to the prescriptions foreseen by technical
standards in force and by the manufacturer's use and maintenance booklet.
| ENGLISH
9
HYDRAULIC SYSTEM
Certain concepts referring to the Italian UNI 10412-2 (2009) Standard are described in this chapter.
As previously described, when installing, all national, regional, provincial and town council Standards in force provided by the
country in which the appliance has been installed must be complied with.
During installation of the stove it is MANDATORY to adjust the system with a manometer in order to display the water pressure.
INSTALLATION AND SAFETY DEVICES
The installation, relative system connections, commissioning and inspection of correct functioning must be carried out perfectly,
in full compliance with Standards in force, national, regional and municipal, as well as these instructions.
For Italy, installation must be carried out by professionally authorised sta (Ministerial Decree dated 22.01.08 n°37).
Extraame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system.
SAFETY DEVICES FOR CLOSED VESSEL SYSTEM
According to the UNI 10412-2 (2009) Standard in force in Italy, the closed systems must have: safety valve, pump control
thermostat, acoustic alarm activation thermostat, temperature indicator, pressure indicator, acoustic alarm, regulation automatic
circuit breaker switch, automatic circuit breaker block switch (block thermostat), circulation system, expansion system, safety
dissipation system incorporated with the generator with thermal safety valve (self-activated), whenever the appliance does not
have a temperature self-adjustment system.
DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD
The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the ow connection.
Whenever the generators lack a device, those missing can be installed on the generator ow pipe, within a distance no greater
than 1m from the machine.
| ENGLISH
TABLE OF SAFETY DEVICES FOR CLOSED VESSEL SYSTEM
AND NOT PRESENT IN THE PRODUCT
Safety valve R
Pump control thermostat (it is managed by the water
probe and the board program) R
Acoustic alarm activation thermostat
Water temperature indicator (display) R
Pressure indicator
Acoustic alarm
Regulation automatic circuit breaker switch (managed
by board program) R
Minimum and maximum pressure pressure switch R
Water overheating automatic circuit breaker switch (block
thermostat) R
Circulation system (pump) R
Expansion system R
SAFETY DEVICES
CIRCUIT BOARD:
Intervenes directly by sending the product into alarm conditions until
complete cooling, in the case of: breakage of ue gas motor, pellet
feed motor breakage, black out (if more than 10 seconds), no ignition
FLOW SENSOR:
In the event of inadequate ow, it takes the machine to alarm conditions
F2.5 A 250V FUSE STOVES:
Protect the machine from violent current drops
85 CALIBRATED MECHANICAL BULB WITH MANUAL REARM:
Intervenes by blocking fuel feed whenever the pellet tank t° reaches
the limit of 85°C. Rearm must be performed by qualied sta and/
or the manufacturer's technical after-sales assistance.
100°C CALIBRATED MECHANICAL BULB WITH MANUAL REARM:
Intervenes by blocking the fuel feed whenever the t° of the water
inside the product is near to 100°. Rearm must be performed by
qualied sta and/or the manufacturer's technical after-sales
assistance.
MINIMUM AND MAXIMUM PRESSURE SWITCH:
Intervenes in the event of inadequate water pressure. Rearm must
be performed by qualied sta and/or the manufacturer's
technical after-sales assistance.
MECHANICAL AIR PRESSURE SWITCH:
Blocks the pellet in the event of insucient depression
10
COMPONENT DISTANCE
Temperature safety sensors On the machine or not exceeding 30 cm
Missing devices because not as per standard Not exceeding one metre, on the ow pipe
The domestic heating appliances with automatic feeding must: be supplied with a fuel block thermostat or be supplied with a
cooling circuit set-up by the appliance manufacturer.
The cooling circuit must be activated by a heat safety valve such to guarantee that the limit temperature set by the Standard is
not exceeded.
Connection between the power supply unit and the valve must be free from interceptions.
The pressure upstream from the cooling circuit must be at least 1.5 bar.
TYPE OF SYSTEM
There are two dierent types of system:
Open vessel system and closed vessel system.
The product has been designed and realised to work with closed vessel systems.
CLOSED VESSEL SYSTEM
System in which the water it contains is not in direct or indirect communication with the atmosphere. Generally, the closed
vessel system has one of the following expansion vessels:
Pre-loaded closed expansion vessel with membrane impermeable to the passage of gases.
Automatic closed expansion system with compressor and membrane impermeable to the passage of gases.
Automatic closed expansion system with transfer pump and membrane impermeable to the passage of gases.
Expansion system without diaphragm.
GENERALITY
The closed systems must have:
Safety valve
Pump control thermostat
Acoustic alarm activation thermostat
Temperature indicator
Pressure indicator
Acoustic alarm
Adjustment automatic circuit breaker switch
Automatic circuit breaker switch (block thermostat)
Circulation system
Expansion system
Safety dissipation system incorporated with the generator with thermal safety valve (self-activated), whenever the
appliance does not have a temperature self-adjustment system
SAFETY VALVES
The load capacity of the safety valve must allow the discharge of a quantity of vapour, not lower than: Q / 0.58 [kg/h] where: Q
is the useful outlet power to the generator water expressed in kilowatt. The diameter of the minimum net transversal section
of the valve inlet must not be lower than 15 mm. The valve load pressure, equal to the calibration pressure, increased by the
overpressure, cannot exceed the maximum exercise pressure of the heat generator. The designer must check that the maximum
pressure existing in every point of the system, does not exceed the maximum exercise pressure of its every component . The
safety valve must be connected to the highest part of the heat generator or outlet pipes, immediately near the generator. The
length of the pipes route included between the attachment to the generator and the safety valve must not be more than 1 m.
The connection piping of the safety valve to the heat generator must not be traceable and must not present, in any point, a
| ENGLISH
T2
T3
A
B
AUX
STBY
T1
14
T2
T3
B
T1
AUX
STBY
A
20
1 2
3
SI
TM
S
G
VB
VMTA
LP 14 LP 20
12
HYDRAULIC SYSTEM BASIC LAYOUT
NOTA BENE:
the drawing in the gure is an example.
| ENGLISH
KEY
APrimary air inlet Ø 60mm
B Smoke exhaust outlet Ø 120mm
CPump (in the models envisioned) 1/2 "
T1 3 bar safety drain 1/2 "
T2 Boiler ow/output 1"
T3 Boiler return/inlet 1"
M Manometer
T Thermometer
G Filling system
SSafety valve discharge
VB Balance valve
YES System exhaust
VMTA Thermostatic mixer valve 55°C
IT IS RECOMMENDED TO CONSULT THE TEMPLATES MANUAL AT FOR FURTHER INFORMATION RELATIVE
TO THE HYDRAULIC CONNECTIONS, AIR INTAKE/FLUE EXHAUST AND DIMENSION SPECIFICATIONS OF THE
PRODUCT IN QUESTION.
BCA
S
16
| ENGLISH
INSTALLATION
Installation in premises with re hazards is forbidden. Installation in residential premises (except for sealed operation appliances)
is also forbidden:
in which there are liquid fuel-operated appliances with continuous or intermittent operation, which draw the combustion
air in the room in which they are installed, or
in which there are type B gas appliances intended for room heating, with or without production of domestic hot water and
in adjacent and adjoining premises, or
in which, in any case, the depression measured during installation between the internal and external environment is
greater than 4 Pa
Installations in bathrooms, bedrooms and studio ats
Installation in bathrooms, bedrooms and studio ats is only allowed for sealed or closed hearth appliances with ducted
combustion air taken from the outside.
Installation premises requirements
The support surfaces and/or points must have a suitable load-bearing capacity to support the weight of the appliance, of the
accessories and coatings.
The adjacent, side and rear walls and the supporting surface must be made of non-combustible material according to the table
REFERENCES INFLAMMABLE OBJECTS NONINFLAMMABLE OBJECTS
A 200 mm 100 mm
B 1500 mm 750 mm
C 200 mm 100 mm
In any case the temperature of the adjacent combustible materials must not reach a temperature equal to or greater than the
room temperature increased by 65°C.
The minimum volume of the premises in which to install the appliance must be greater than 15 m³.
Air inlet
S= oor protection
Flue
Inspection
gure 1 gure 2
17
| ENGLISH
VENTILATION AND AERATION OF THE INSTALLATION PREMISES
Ventilation is deemed sucient when the room is equipped with air inlets according to the table:
Air inlet
See gure 2
Appliance categories Reference standard
Percentage of the
net opening section with
respect to the appliance fumes
outlet section
Minimum net opening value of
the ventilation duct
Boilers UNI EN 303-5 50% 100 cm²
In any case ventilation is deemed sucient when the pressure dierence between the external and internal environment is
equal to or less than 4 Pa.
In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration
and/or ventilation opening. The air inlets must meet the following requirements:
they must be protected with grids, metal mesh, etc., but without reducing the net useful section;
they must be made so as to make the maintenance operations possible;
positioned so that they cannot be obstructed;
The air ow can also be obtained from a room adjacent to that of installation (indirect aeration and ventilation), as long as the
ow takes place freely through permanent openings communicating with the outside.
The adjacent room cannot be used as a garage, warehouse of combustible material or for any other activity with a re hazard,
bathroom, bedroom or common room of the building.
FUMES EXHAUST SYSTEM
GENERAL REQUIREMENTS
Each appliance must be connected to a suitable fumes exhaust system and ensure adequate dispersion of the combustion
products into the atmosphere. The combustion products must discharged above the roof. Direct discharge from the wall or
towards closed spaces is forbidden, even with clear skies.
In particular, it is forbidden to use exible and extendible metal pipes.
The chimney should only receive the exhaust of the smoke duct connected to the appliance; collective ues or conveying
exhausts from hoods above cooking appliances of any kind, or exhausts from other generators into the chimney itself or smoke
duct are not allowed.
The smoke duct and the chimney must be connected with a continuity solution, in order to prevent the chimney from resting
on the appliance.
It is forbidden to have other air supply channels and pipes for plant engineering transit inside the fumes exhaust systems,
especially if over-sized.
The components of the fumes exhaust system must be chosen in relation to the type
of appliance to be installed in compliance with:
in the event of metal chimneys, UNI/ TS 11278, with particular attention to what is stated in the specication;
in the event of non-metallic chimneys: UNI EN 13063-1 and UNI EN 13063-2, UNI EN 1457, .-UNI EN 1806; considering
especially:
temperature class;
pressure class (fumes seal) at least equal to the seal required for the appliance;
moisture resistance (resistance to condensation);
class or level of corrosion and specication of the materials constituting the inner wall in contact with the fumes.
soot re resistance class;
minimum distance from combustible materials
The installer of the fumes exhaust system, once the installation is complete and the relevant checks and inspections have been
made, must x the chimney plaque supplied by the manufacturer with the product in a visible manner, near the replace, and
which must be completed with the following information:
a
a
b.1
b
a
a
a
a
b.1
b.1
b b
OK OK
18
| ENGLISH
SMOKE DUCT
General requirements
The smoke ducts must be installed in compliance with the following general requirements:
they must be insulated if they cross through rooms that are not to be heated or outside the building;
they must not cross rooms in which the installation of combustion appliances is forbidden, nor in other premises
compartmentalised against re or with a re hazard, nor in rooms and/or areas that cannot be inspected;
they must be installed so as to allow normal thermal expansion;
they must be tted to the opening of the chimney without protruding inwards;
the use of exible metal pipes to connect the appliance to the chimney is not allowed;
nominal diameter;
distance from combustible materials, indicated in millimetres, followed by the arrow and ame symbol;
installer data and date of installation.
Every time one must cross combustible materials, the following indications must be complied with:
SYMBOL DESCRIPTION QUOTAMM
bMinimum distance of combustible materials from the intrados of the framework/oor/wall 500
b.1 Minimum distance of combustible materials from the extrados of the framework/oor 500
a Minimum distance from combustible materials dened by the manufacturer G(xxx)
The single wall pipes are indicated in white.
The insulated double wall chimney systems are indicated in grey.
One can disregard the quota only in the event of using an appropriate heat protection screen (for example: wall plate) to
protect the intrados of the framework/oor
Chimney Chimney
Incorrect Correct
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame LP20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame LP20 in the language / languages: English as an attachment in your email.

The manual is 4.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame LP20

Extraflame LP20 User Manual - German - 40 pages

Extraflame LP20 User Manual - Dutch - 40 pages

Extraflame LP20 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info