28 ENGLISH
FRONT AIR
This menu allows the front ventilation motor speed to be set. Range: (comfort, auto).
If comfort mode is selected, the front air speed is reduced.
To guarantee ecient combustion, front air is excluded when the appliance is running at minimum power.
To set: OK > FRONT AIR >SET
EASY SETUP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the EASY SETUP function, it is possible to change the calibration of the volumetric weight by increasing or decreasing
the preset values.
In the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value which
is 0
If you notice an excessive deposit on the burning pot, access the EASY SETUP program and lower the value by one unit to “- 1”; then wait
until the next day and if there is no improvement, decrease again, to a maximum of “- 3”. Instead, if it is necessary to increase the calibration
of the volumetric weight of the pellet, change the factory value from “0” to “+ 1, + 2, + 3” as required.
To set: OK > EASY SETUP
EXCESSIVE PELLET DEPOSIT IN BURN POT NORMAL OPERATION MINIMUM PELLET DEPOSIT IN BURN POT
-3 -2 -1 0 +1 +2 +3
THIRD DECREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
SECOND
DECREASE
RANGE IF
THE FIRST IS
INSUFFICIENT
FIRST DECREASE
RANGE (TEST FOR
1 DAY )
OPTIMAL FACTORY
VALUE
FIRST INCREASE
RANGE
SECOND
INCREASE RANGE
IF THE FIRST IS
INSUFFICIENT
THIRD INCREASE
RANGE IF THE
FIRST TWO ARE
INSUFFICIENT
N.B.: If these adjustments do not solve the problem of pellet deposits in the burn pot, please contact your local service centre.
CHRONO
This function allows stove ignition and switch-o to be automatically programmed.
The factory setting for CHRONO is o.
The chrono allows the programming of 4 time slots per day, which can be used every day of the week.
For each time slot, it is possible to
set ignition and switch-o times, specic days of application, desired temperature and set power. Current day and time settings
are essential for the correct operation of the Chrono.
Recommendations
Before using the chrono function, it is necessary to set the current day and time. Therefore, check that the points in the sub-section
DATETIME have been followed. To use the chrono function correctly, it must not only be programmed, but also enabled. The 4 time
slots can be overlapped using the ignition and switch-o time settings. In this way, it is possible to create a combination of time slots
with dierent temperatures and power levels, without changing the status of the stove.
N.B.: in the case of overlapping time slots, the stove will remain on until the last switch-o time.
AIR DUCTING 1
This menu allows a choice of two operating modes for air ducting 1, and the regulation of the set temperature if an NTC probe is connected
in input: AUTO - COMFORT
To set: OK > AIR DUCTING 1 > SET
To adjust the temperature: OK > AIR DUCTING 1 > TEMPERATURE
AIR DUCTING 2
This menu allows a choice of two operating modes for air ducting 2, and the regulation of the set temperature if an NTC probe is connected
in input: AUTO - COMFORT
To set: OK > AIR DUCTING 2 > SET
To adjust the temperature: OK > AIR DUCTING 2 > TEMPERATURE
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame INSERTO COMFORT P85 PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame INSERTO COMFORT P85 PLUS in the language / languages: English as an attachment in your email.

The manual is 6,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame INSERTO COMFORT P85 PLUS

Extraflame INSERTO COMFORT P85 PLUS User Manual - German - 40 pages

Extraflame INSERTO COMFORT P85 PLUS User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info