HP30 EVO HP15 - 22 EVO
ENGLISH
STBY  ADDITIONAL ROOM THERMOSTAT
PLEASE NOTE : Installation must be performed by an authorised technician
Is it possible to thermostat a room adjacent to the room where it was placed the generator just connecting a room thermostat according to the
procedure described in the next step (it is advisable to position the optional mechanical thermostat at a height of 1.50 m from the oor) . The
generator functioning with the external thermostat connected to the TA terminal can be dierent on the basis of the activation or disabling
of the STBY function.
The TA clamp leaves the factory jumpered, therefore it is always with closed contact (on request).
ADDITIONAL ROOM THERMOSTAT FUNCTIONING WITH STBY ACTIVE STBY ON
When the contact or the external thermostat is satised (open contact / temperature reached), the generator will switch o. As soon as the
contact or external thermostat switches to the "not satised" status (closed contact/temperature to be reached) it will re-ignite.
PLEASE NOTE: the generator operation depends on the temperature of the water inside the thermal-product and relevant factory
setting. If the generator is in H OFF (water temperature reached), any additional contact or thermostat request will be ignored.
OPERATION OF THE AMBIENT ADDITIONAL THERMOSTAT WITH STBY DISABLED STBY OFF
When the contact or external thermostat is satised (open contact / temperature reached), the generator will go to minimum. As soon as the
contact or external thermostat switches to the "not satised" status (closed contact / temperature to be reached) the generator will start to
work again at the pre-set power.
PLEASE NOTE: the generator operation depends on the temperature of the water inside the general and relevant factory setting. If
the generator is in H OFF (water temperature reached), any additional contact or additional thermostat request will be ignored.
ADDITIONAL ROOM THERMOSTAT INSTALLATION
Switch the appliance o using the master switch positioned on the rear of the generator.
Remove the plug from the socket.
Refer to the electrical diagram to connect the two thermostat cables onto the relative clamps positioned on the rear of the machine, one
is red and the other one is black (TA clamp).
AUX
IN CASE YOU ARE USING THE MANUFACTURER'S POWER LINE COMMUNICATION DEVICES, A QUALIFIED TECHNICIAN MUST
PERFORM THE CONNECTION DIRECTLY ON THE BOARD. FOR MORE INFORMATION, CONTACT YOUR LOCAL DEALER.
H
TA
TA
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame HP30 EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame HP30 EVO in the language / languages: English as an attachment in your email.

The manual is 3,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame HP30 EVO

Extraflame HP30 EVO User Manual - German - 36 pages

Extraflame HP30 EVO User Manual - Dutch - 36 pages

Extraflame HP30 EVO User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info