696315
11
Zoom out
Zoom in
Previous page
1/36
Next page
11ENGLISH
HYDRAULIC SYSTEM
Certain concepts referring to the Italian Standard UNI 10412-2 (2009) are described in this chapter.
As previously described, when installing, all national, regional, provincial and council Standards in force provided by the country in which the
appliance has been installed must be complied with.
During installation of the generator it is MANDATORY to adjust the system with a manometer in order to display the water pressure.
TABLE OF SAFETY DEVICES FOR CLOSED VESSEL SYSTEM AND NOT PRESENT IN THE PRODUCT
Safety valve
p
Pump control thermostat (it is managed by the water probe and the board program)
p
Water temperature indicator (display)
p
Pressure transducer with display
p
Automatic circuit breaker adjustment switch (managed by board program)
p
Pressure transducer with minimum and maximum pressure switch alarm
p
Water overheating automatic circuit breaker switch (block thermostat)
p
Circulation system (pump)
p
Expansion system
p
INSTALLATION AND SAFETY DEVICES
The installation, relative system connections, commissioning and inspection of correct functioning must be carried out perfectly, in full
compliance with Standards in force, national, regional and municipal, as well as these instructions. For Italy, installation must be carried out by
professionally qualied sta (Ministerial Decree dated 22.01.08 n°37).
Extraame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system.
TYPE OF SYSTEM
There are 2 dierent types of system:
Open vessel system and closed vessel system.
The product has been designed and made to work with closed vessel systems.
Pay attention to the correct sizing of the system:
generator power compared to the thermal requirement
possible need for a buer tank
SAFETY DEVICES FOR CLOSED VESSEL SYSTEM
In accordance with the UNI 10412-2 (2009) regulation in force in Italy, all the closed systems must be tted with: safety valve, pump control
thermostat, temperature indicator, pressure indicator, automatic circuit breaker block switch (block thermostat), circulation system,
expansion system, and safety dissipation built-in to the generator with thermal safety valve (self-activated), if the appliance does not have a
temperature self-adjustment system.
J
CHECK THAT THE PRELOAD OF THE EXPANSION VESSEL IS SET TO 1.5 BAR.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Extraflame HP30 EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Extraflame HP30 EVO in the language / languages: English as an attachment in your email.

The manual is 3,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Extraflame HP30 EVO

Extraflame HP30 EVO User Manual - German - 36 pages

Extraflame HP30 EVO User Manual - Dutch - 36 pages

Extraflame HP30 EVO User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info